What are the uses of impedance, power factor and phase Angle in alternating current? What is the relationship between these factors?

Encyclopedia
09/27/2024

The role and relation of impedance, power factor and phase Angle in alternating current


In the analysis of AC circuits, impedance, power factor and phase Angle are three basic concepts, each of which has a specific purpose and a close relationship with each other.


Impedance


Impedance is a comprehensive parameter that describes the resistance, inductance and capacitance of the AC circuit to hinder the current flow. It consists of resistance (R), inductive reactance (XL), and capacitive reactance (XC), but is not simply added together, but rather their sum on the vector 2. The unit of impedance is ohm (Ω), and the size of the impedance is related to the frequency in the circuit, the higher the frequency, the smaller the capacitive reactance, the greater the inductive reactance; And vice versa. The value of the impedance changes with frequency, which is crucial for understanding and designing AC circuits.


Power factor


The power factor is the ratio of the active power (P) to the apparent power (S) in an AC circuit, usually expressed as cosφ. The power factor reflects the ratio of the actual power consumed in a circuit to the maximum power that the circuit can provide. Ideally, the power factor is 1, indicating that the circuit is perfectly matched and there is no reactive power loss. When the value is lower than 1, it indicates the loss of reactive power and reduces the efficiency of the grid. The power factor Angle (φ) is the inverse tangent of the power factor cosφ, usually between -90 degrees and +90 degrees, indicating the phase difference between current and voltage.


Phase Angle


The phase Angle is the phase difference between the voltage and current waveforms, usually denoted by θ. In an AC circuit, both voltage and current are sinusoidal waveforms, and the phase difference determines the energy flow in the circuit. When the voltage and current are in phase, the phase difference is 0 degrees, and the power is maximum. When the voltage leads the current by 90 degrees or lags by 90 degrees, it corresponds to reactive power and inductive load or capacitive load, respectively. The impedance Angle (φ) is actually the power factor Angle, which is the Angle difference between the voltage and the current phasor, and for impedance components (such as resistors, inductors and capacitors), the impedance Angle is equal to the power factor Angle.


Relationship summary


There are the following relationships between impedance, power factor and phase Angle:


Impedance (Z) is the complex amount of voltage and current in the circuit, including the vector sum of resistance, inductive reactance and capacitive reactance, reflecting the total obstruction of the circuit to the current.


The power factor (cosφ) is the cosine value of the impedance Angle, indicating the ratio of active power to apparent power, reflecting the efficiency of the circuit.


The phase Angle (θ or φ) is the phase difference between the voltage and current waveform, which determines the energy flow of the circuit and is the specific embodiment of the power factor Angle.


Understanding these concepts helps to analyze and optimize AC circuit design, improve energy efficiency and reduce reactive power loss.


Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
Frequency division method for measuring grid-to-ground insulation parameters
Frequency division method for measuring grid-to-ground insulation parameters
The frequency division method enables the measurement of grid-to-ground parameters by injecting a current signal of a different frequency into the open delta side of the potential transformer (PT).This method is applicable to ungrounded systems; however, when measuring the grid-to-ground parameters of a system where the neutral point is grounded via an arc suppression coil, the arc suppression coil must be disconnected from operation beforehand. Its measurement principle is shown in Figure 1.As
Leon
07/25/2025
The insulation parameters of the power grid to ground are measured by the tuning method
The insulation parameters of the power grid to ground are measured by the tuning method
The tuning method is suitable for measuring the ground parameters of systems where the neutral point is grounded via an arc suppression coil, but not applicable to ungrounded neutral point systems. Its measurement principle involves injecting a current signal with continuously varying frequency from the secondary side of the Potential Transformer (PT), measuring the returned voltage signal, and identifying the system's resonant frequency.During the frequency sweeping process, each injected heter
Leon
07/25/2025
Effect of Transition Resistance at the Grounding Point on the Rising Speed of Zero - sequence Voltage
Effect of Transition Resistance at the Grounding Point on the Rising Speed of Zero - sequence Voltage
In an arc - suppression coil grounding system, the rising speed of the zero - sequence voltage is greatly affected by the value of the transition resistance at the grounding point. The larger the transition resistance at the grounding point, the slower the rising speed of the zero - sequence voltage.In an ungrounded system, the transition resistance at the grounding point has basically no impact on the rising speed of the zero - sequence voltage.Simulation Analysis: Arc - suppression Coil Ground