Wiring method of motor open-phase protection

Master Electrician
07/02/2024

Wiring method of motor open-phase protection

电机缺相保护.jpg

Master Electrician

We aim to gather electrical knowledge and share it with others.

What are the differences between an alternating current generator and a direct current generator?
What are the differences between an alternating current generator and a direct current generator?
Main Differences Between AC and DC GeneratorsAn electrical machine is a device that converts mechanical energy into electrical energy and vice versa. A generator is a type of such machine that converts mechanical energy into electrical energy. However, the electrical energy generated can be in either alternating current (AC) or direct current (DC) form. Thus, the primary difference between AC and DC generators is that they generate alternating current and direct current respectively. While there
Edwiin
07/18/2025
Compound Wound Generator
Compound Wound Generator
Compound Wound Generator FundamentalsA compound wound generator features two field windings per pole: one series-connected with few turns of thick wire, and the other shunt-connected with many turns of fine wire parallel to the armature windings.In essence, a compound generator integrates both shunt and series field windings. It is classified as:Cumulative compounded: Series winding flux reinforces shunt winding flux.Differentially compounded: Series winding flux opposes shunt winding flux.Two c
Edwiin
05/27/2025
Dynamic Braking or Rheostatic Braking of DC Motor
Dynamic Braking or Rheostatic Braking of DC Motor
Dynamic Braking Principles in DC MotorsIn dynamic braking, a braking resistor Rbis connected across the armature immediately after disconnecting the DC motor from the supply. The motor then functions as a generator, producing braking torque.Dynamic Braking ConfigurationsTwo connection methods enable braking operation:Separately Excited/Shunt Motor as a Separately Excited Generator:Flux is maintained constant for consistent braking performance.Self-Excited Shunt Generator:Field winding is connect
Edwiin
05/27/2025
Working Principle of a Synchronous Motor
Working Principle of a Synchronous Motor
Structure and Excitation of Synchronous MotorsThe synchronous motor consists of two primary components: the stator (stationary part) and the rotor (rotating part). The stator is energized by a three-phase AC supply, while the rotor is excited by a DC supply.Excitation Principle:Excitation refers to the process of inducing magnetic fields in both the stator and rotor, transforming them into electromagnets. This magnetic coupling is essential for converting electrical energy into mechanical rotati
Edwiin
05/26/2025