What is an Integral Controller?

Encyclopedia
Field: Encyclopedia
0
China


What is an Integral Controller?


Integral controller definition


Integral controller is another basic control algorithm in automatic control systems, usually represented by the letter "I". The integral controller adjusts the output of the controller by accumulating error signals to eliminate steady-state errors in the system.


Basic principle


The basic idea of the integral controller is to accumulate error signals during the control process and use the accumulated results to adjust the output of the controller.


c628f90ec523a767d3003722f6444dfd.jpeg



u(t) is the output signal of the controller.

Ki is an Integral Gain, which determines the amplification of the output signal to the accumulation of errors.

e(t) is the error signal, defined as e(t)=r(t)−y(t), where r(t) is the set value and y(t) is the actual measured value.


Controller output


The output of the integration controller can be expressed as:


59ab3b97cc031fc7f2f5194c55bfa5a8.jpeg


Ki here is a constant that can be adjusted to change the speed and strength of the controller's response to the accumulation of errors.


Advantage


  • Eliminate steady-state error: The integral controller can eliminate steady-state error in the system, so that the system is finally stable at the set value.



  • Improve accuracy: By accumulating error signals, the control accuracy of the system can be improved.



Shortcoming


  • Slow response: Due to the need to accumulate error signals, the response speed of the integral controller is slow.



  • Overtuning: If the integration gain is not selected properly, it may lead to overtuning of the system.



  • Stability issues: Integral controllers can cause the system to become unstable, especially in the presence of high-frequency noise.



Apply


  • Temperature control system: The power of the heater is adjusted by accumulating temperature errors to ensure that the final temperature is stable at the set value.



  • Flow control system: Adjust the opening of the valve by accumulating flow errors to ensure that the flow is stable at the set value.



  • Pressure control system: The output of the pump is adjusted by accumulating pressure errors to ensure that the pressure in the pipeline is stable at the set value.


  • Motor control system: By accumulating motor speed error to adjust the output of the motor to ensure that the motor speed is stable at the set value.


Give a tip and encourage the author!

Recommended

Classification of Equipment Defects for Relay Protection and Safety Automatic Devices in Substations
In daily operations, various equipment defects are inevitably encountered. Whether maintenance personnel, operation and maintenance staff, or specialized management personnel, all must understand the defect classification system and adopt appropriate measures according to different situations.According to Q/GDW 11024-2013 "Operation and Management Guide for Relay Protection and Safety Automatic Devices in Smart Substations," equipment defects are classified into three levels based on severity an
12/15/2025
Under What Conditions Will the Line Circuit Breaker Auto-Reclosing Signal Be Locked Out?
The line circuit breaker auto-reclosing signal will be locked out if any of the following conditions occur:(1) Low SF6 gas pressure in circuit breaker chamber at 0.5MPa(2) Insufficient energy storage in circuit breaker operating mechanism or low oil pressure at 30MPa(3) Busbar protection operation(4) Circuit breaker failure protection operation(5) Line distance protection zone II or zone III operation(6) Short lead protection operation of circuit breaker(7) Presence of remote tripping signal(8)
12/15/2025
Application of Auto-Reclosing Residual Current Protective Devices in Lightning Protection for Communication Power Supplies
1. Power Interruption Problems Caused by RCD False Tripping During Lightning StrikesA typical communication power supply circuit is shown in Figure 1. A residual current device (RCD) is installed at the power supply input terminal. The RCD primarily provides protection against electrical equipment leakage currents to ensure personal safety, while surge protective devices (SPDs) are installed on power supply branches to protect against lightning intrusions. When lightning strikes occur, the senso
12/15/2025
Reclosing Charge Time: Why Does Reclosing Require Charging? What Effects Does Charging Time Have?
1. Function and Significance of Reclosing ChargingReclosing is a protective measure in power systems. After faults such as short circuits or circuit overloads occur, the system isolates the faulty circuit and then restores normal operation through reclosing. The function of reclosing is to ensure continuous operation of the power system, improving its reliability and safety.Before performing reclosing, the circuit breaker must be charged. For high-voltage circuit breakers, the charging time is g
12/15/2025
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.