What is a Shunt Capacitor?

Encyclopedia
Field: Encyclopedia
0
China


What is a Shunt Capacitor?


Shunt Capacitor Definition


A shunt capacitor is defined as a device used to improve power factor by providing capacitive reactance to counteract inductive reactance in electrical power systems.


Power Factor Compensation


Shunt capacitors help improve the power factor, which reduces line losses and improves voltage regulation in power systems.


Capacitor Bank


The capacitor reactance is generally applied to the system by using static capacitor in shut or series with system. Instead of using a single unit of capacitor per phase of the system, it is quite effective to use a bank of capacitor units, in the view of maintenance and erection. This group or bank of capacitor units is known as capacitor bank.

 

There are mainly two categories of capacitor bank according to their connection arrangements.

 


  • Shunt capacitor.

  • Series capacitor.


The Shunt capacitor is very commonly used.


Connection of Shunt Capacitor Bank


The capacitor bank can be connected to the system either in delta or in star. In star connection, the neutral point may be grounded or not depending upon protection scheme for capacitor bank adopted. In some cases the capacitor bank is formed by double star formation.Generally large capacitor bank in electrical substation is connected in star.


The grounded star connected bank has some specific advantages, such as,


  • Reduced recovery voltage on circuit breaker for normal repetitive capacitor switching delay.



  • Better surge protection.



  • Comparatively reduced over voltage phenomenon.


  • Lesser cost of installation.


In a solidly grounded system, the voltage of all three phases of a capacitor bank remains fixed, even during two-phase operation.


Location Considerations


Ideally, a capacitor bank should be placed near reactive loads to minimize reactive power transmission across the network. When a capacitor and load are connected together, they disconnect simultaneously, preventing overcompensation. However, it’s not practical or economical to connect a capacitor to each individual load due to varying load sizes and availability of capacitors. Additionally, not all loads are connected continuously, so the capacitors may not be fully utilized.


Hence, capacitor, is not installed at small load but for medium and large loads, capacitor bank can be installed at consumer own premises. Although the inductive loads of medium and large bulk consumers are compensated, but still there would be considerable amount of VAR demand originated from different uncompensated small loads connected to the system. In addition to that, inductance of line and transformer also contribute VAR to the system. On viewing of these difficulties, instead of connecting capacitor to each load, large capacitor bank is installed at main distribution sub-station or secondary grid sub-station.

  


Give a tip and encourage the author!

Recommended

Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
01/30/2026
Classification of Equipment Defects for Relay Protection and Safety Automatic Devices in Substations
In daily operations, various equipment defects are inevitably encountered. Whether maintenance personnel, operation and maintenance staff, or specialized management personnel, all must understand the defect classification system and adopt appropriate measures according to different situations.According to Q/GDW 11024-2013 "Operation and Management Guide for Relay Protection and Safety Automatic Devices in Smart Substations," equipment defects are classified into three levels based on severity an
12/15/2025
Under What Conditions Will the Line Circuit Breaker Auto-Reclosing Signal Be Locked Out?
The line circuit breaker auto-reclosing signal will be locked out if any of the following conditions occur:(1) Low SF6 gas pressure in circuit breaker chamber at 0.5MPa(2) Insufficient energy storage in circuit breaker operating mechanism or low oil pressure at 30MPa(3) Busbar protection operation(4) Circuit breaker failure protection operation(5) Line distance protection zone II or zone III operation(6) Short lead protection operation of circuit breaker(7) Presence of remote tripping signal(8)
12/15/2025
Application of Auto-Reclosing Residual Current Protective Devices in Lightning Protection for Communication Power Supplies
1. Power Interruption Problems Caused by RCD False Tripping During Lightning StrikesA typical communication power supply circuit is shown in Figure 1. A residual current device (RCD) is installed at the power supply input terminal. The RCD primarily provides protection against electrical equipment leakage currents to ensure personal safety, while surge protective devices (SPDs) are installed on power supply branches to protect against lightning intrusions. When lightning strikes occur, the senso
12/15/2025
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.