Switchable Capacitor Bank

Encyclopedia
Field: Encyclopedia
0
China

Switchable Capacitor Bank Definition


A switchable capacitor bank is defined as a set of capacitors that can be turned on or off to manage reactive power in an electrical system.


Purpose


The main purpose of a switched capacitor bank is to improve power factor and voltage profile by balancing the inductive reactive power in the system.


Reactive Power Management


Switched capacitor banks help in reducing overall reactive power, which enhances system efficiency and stability.


Automatic Control


These banks can be controlled automatically based on system voltage, current load, reactive power demand, power factor, or timers.


Benefits


  • A capacitor bank can be automatically switched ON and OFF depending upon condition of different parameters of the system-Capacitor Bank can be controlled automatically depending upon voltage profile of the system. Since the voltage of the system depends upon the load, hence capacitor may be switched on just below a certain preset voltage level of the system and also it should be switched OFF above a preset higher voltage level.



  • Capacitor bank can also be switched ON and OFF depending upon the Amp of the load.



  • The function of a capacitor bank is to neutralize reactive power in the system, measured in KVAR or MVAR. The switching of the capacitor bank depends on the reactive power load. When KVAR demand exceeds a preset value, the bank switches on and switches off when the demand drops below another preset value.



  • Power factor can be used as another system parameter to control a capacitor bank. When the power factor of the system comes below a predetermined value the bank is automatically switched ON to improve the pf.



  • A capacitor bank can also be controlled by a timer. It can be set to switch off at the end of every factory shift using a timer.

  


Give a tip and encourage the author!

Recommended

Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
01/30/2026
Classification of Equipment Defects for Relay Protection and Safety Automatic Devices in Substations
In daily operations, various equipment defects are inevitably encountered. Whether maintenance personnel, operation and maintenance staff, or specialized management personnel, all must understand the defect classification system and adopt appropriate measures according to different situations.According to Q/GDW 11024-2013 "Operation and Management Guide for Relay Protection and Safety Automatic Devices in Smart Substations," equipment defects are classified into three levels based on severity an
12/15/2025
Under What Conditions Will the Line Circuit Breaker Auto-Reclosing Signal Be Locked Out?
The line circuit breaker auto-reclosing signal will be locked out if any of the following conditions occur:(1) Low SF6 gas pressure in circuit breaker chamber at 0.5MPa(2) Insufficient energy storage in circuit breaker operating mechanism or low oil pressure at 30MPa(3) Busbar protection operation(4) Circuit breaker failure protection operation(5) Line distance protection zone II or zone III operation(6) Short lead protection operation of circuit breaker(7) Presence of remote tripping signal(8)
12/15/2025
Application of Auto-Reclosing Residual Current Protective Devices in Lightning Protection for Communication Power Supplies
1. Power Interruption Problems Caused by RCD False Tripping During Lightning StrikesA typical communication power supply circuit is shown in Figure 1. A residual current device (RCD) is installed at the power supply input terminal. The RCD primarily provides protection against electrical equipment leakage currents to ensure personal safety, while surge protective devices (SPDs) are installed on power supply branches to protect against lightning intrusions. When lightning strikes occur, the senso
12/15/2025