• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


The charging capacitor is calculated by the discharge time of the resistor

Encyclopedia
Field: Encyclopedia
0
China


The calculation of the time for the capacitor to discharge through the resistor involves the characteristics of the RC circuit (that is, the circuit consisting of the resistor and the capacitor). In RC circuits, the process of capacitor discharge can be described by an exponential function.


Discharge time calculation formula


When a capacitor is discharged, the change of its voltage V(t) with time t can be expressed by the following formula:


f85ce20200aaf850bc965d5b2869be21.jpeg


  • V(t) is the voltage of the capacitor at time t;



  • V0 is the initial voltage (i.e. the voltage at which the capacitor starts discharging);



  • R is the resistance in the circuit (ohms, Ω);



  • C is the capacitance of the capacitor (farad, F);



  • e is the base of the natural logarithm (approximately 2.71828);



  • t is time (seconds, s).


Time constant


The time constant τ is the product of RC, which represents the time required for the capacitor to discharge to 1/e of the initial voltage (about 36.8%). The formula for calculating the time constant τ is:


image.png


Sum up


The calculation of capacitor discharge time through resistor is mainly based on exponential attenuation formula. The time constant τ=RC describes the rate at which a capacitor discharges. For the calculation of a specific voltage ratio, the above formula can be used to solve the required time.


Give a tip and encourage the author!

Recommended

Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
01/30/2026
Classification of Equipment Defects for Relay Protection and Safety Automatic Devices in Substations
In daily operations, various equipment defects are inevitably encountered. Whether maintenance personnel, operation and maintenance staff, or specialized management personnel, all must understand the defect classification system and adopt appropriate measures according to different situations.According to Q/GDW 11024-2013 "Operation and Management Guide for Relay Protection and Safety Automatic Devices in Smart Substations," equipment defects are classified into three levels based on severity an
12/15/2025
Under What Conditions Will the Line Circuit Breaker Auto-Reclosing Signal Be Locked Out?
The line circuit breaker auto-reclosing signal will be locked out if any of the following conditions occur:(1) Low SF6 gas pressure in circuit breaker chamber at 0.5MPa(2) Insufficient energy storage in circuit breaker operating mechanism or low oil pressure at 30MPa(3) Busbar protection operation(4) Circuit breaker failure protection operation(5) Line distance protection zone II or zone III operation(6) Short lead protection operation of circuit breaker(7) Presence of remote tripping signal(8)
12/15/2025
Application of Auto-Reclosing Residual Current Protective Devices in Lightning Protection for Communication Power Supplies
1. Power Interruption Problems Caused by RCD False Tripping During Lightning StrikesA typical communication power supply circuit is shown in Figure 1. A residual current device (RCD) is installed at the power supply input terminal. The RCD primarily provides protection against electrical equipment leakage currents to ensure personal safety, while surge protective devices (SPDs) are installed on power supply branches to protect against lightning intrusions. When lightning strikes occur, the senso
12/15/2025
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.