IGZO-TFT-PDK: Thin-Film Flexible Electronics Design Kit, Standard Cell and Design Methodology

IEEE Xplore
Field: Electrical Standards
0
Canada

With the increasing demand for transparent/flexible displays, healthcare sensors, and robotics, there is a need to advance the development of thin-film transistors (TFTs) manufacturing and large-scale circuits. This paper has proposed an IGZO-TFT-PDK to aid the educators and research community to explore the circuit design space of dual-gate IGZO-TFT devices. To solve the tensile force-induced current variation problem in IGZO-TFT devices, an omni-directional device and its layout template with a compensation methodology that mitigates its variation are proposed. A layout template is also proposed to speed up the design development flow of both analog and digital IGZO-TFT circuits. Based on the proposed layout template, a tensile force-insensitive standard cell library is proposed. We have implemented a 32-bit carry select adder to validate the usability of the standard cell library.

Source: IEEE Xplore

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!

Recommended

Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
01/30/2026
Neutral point grounding operation mode for 110kV~220kV power grid transformers
The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
01/29/2026
Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
01/29/2026
Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I