What are the application advantages and development trends of pad-mounted transformers?

Echo
Field: Transformer Analysis
China
In the reconstruction and expansion of modern urban power grids, to optimize the power supply layout, it is required that high - voltage directly enters urban areas, medium - voltage penetrates deep into load centers to shorten the low - voltage power supply radius, and underground cable laying is mostly adopted for urban main roads. Electrical equipment needs to meet the requirements of intelligence, miniaturization, high reliability and aesthetics. The compact substation is widely used in urban distribution networks and load - intensive places due to its economy, convenience and high efficiency.
The compact substation integrates devices such as transformers, high - voltage power - receiving side equipment, and low - voltage power distribution. It is fully sealed and insulated, with a compact and beautiful structure. There is no need for a separate power distribution room, and it can be flexibly installed. It has both the function of power supply and environment embellishment; it supports the rapid conversion of power supply modes to ensure reliable and flexible power supply; it adopts double - fuse protection, special cable heads and high - quality distribution transformers to reduce costs and improve performance.
Structure and Characteristics
It is composed of electrical units such as the high - voltage switch system and is arranged in a fully enclosed and movable steel structure box. The characteristics are as follows:
  • Compact and Space - saving: Integrate high - voltage equipment, reduce the insulation distance, and compress the occupied area and space.
  • Quick Installation: Design and select the type according to requirements. The manufacturer completes the installation and commissioning, and it can be put into operation directly after being placed on - site.
    Low Cost: The equipment cost, pre - investment cost and operation and maintenance cost are all low, with remarkable economy.
  • Flexible Combination: A single box can form a system, and the components have strong universality and interchangeability, which is convenient for maintenance and upgrading.
  • Safe and Reliable: The internal equipment is fully enclosed. The box has anti - corrosion properties and is equipped with an environment - regulating device. There are no exposed conductors, avoiding safety risks.
  • High Automation: Equipped with a microcomputer protection system, it realizes the "four - remote" functions (remote measurement, remote signaling, remote control, remote adjustment), and can perform intelligent regulation, monitoring and alarming.
  • Aesthetic and Adaptable: Small in size, beautifully designed, and can be integrated with the environment by selecting appropriate colors, suitable for urban construction.
Operation Specifications
  • Parallel Operation: Meet the conditions of the same wiring group, the same voltage ratio, and the same impedance voltage; check the load and perform phase verification before operation, and record the results in the switching operation ticket.
  • Power - on and Power - off Operation: Consider the neutral point switching before power - on and power - off; for power - off, first turn off the low - voltage side, then the medium - voltage side, and finally the high - voltage side. First open the circuit breakers on each side, and then open the disconnectors on each side from low to high (for the main transformer disconnector, first pull the transformer side, then the bus side); the power - on sequence is the opposite.
  • On - load Tap - changing Operation: Voltage regulation is required to stabilize the voltage. According to the operation duration and the number of switching times of the tap - changer, oil sample testing, oil replacement, and core - lifting inspection are required.
Conclusion
Following the concept of environmental protection and conservation, the compact substation integrates the traditional transformer into a box - type shell. With the advantages of small size, light weight, low noise, low loss and high reliability, it is widely used in load - intensive places such as industrial and mining enterprises and ports. It effectively optimizes the power supply layout in the urban power grid. Through the optimization of structure and performance, it improves the reliability of power supply and the convenience of operation and maintenance, enhances corrosion resistance and prolongs the service life. It provides strong support for the sustainable development of offshore wind farms and urban distribution networks, and meets the development needs of the modern power system for high efficiency, intelligence and environmental protection.
Give a tip and encourage the author!
Recommended
Why Do Contactors Always Burn Out? Overload and Short-Circuit Protection Must Be Implemented Simultaneously
Contactors are used to close and open loads that require such operations during normal use, particularly for specific activities like medium-voltage public lighting and industrial electric motors.The medium-voltage contactor + fuse combination controller (F-C) can control motors up to 12 kV. However, medium-voltage controllers are also suitable as feeders for other types of loads, especially transformers. For such loads, contactors are usually modified to include mechanical latching, so that the
Echo
09/11/2025
High-Voltage DC Contactor Wiring Essentials: Polarity Requirements and Safety Guidelines
High-Voltage DC Contactors Usually Have Polarity DistinctionsThis is especially true in application scenarios with high current and high voltage.Why Polarity Distinctions ExistArc CharacteristicsDC current has no zero-crossing point, making arc extinction more difficult than that of AC. Polarity (current direction) may affect the stretching and extinguishing effect of the arc.Internal Structural DesignSome contactors optimize arc-extinguishing devices (such as magnetic blowout coils and permanen
Echo
09/09/2025
Working Principle of Low-Voltage Vacuum Contactors and Their Application in DF100A Shortwave Transmitters
In power systems, low-voltage vacuum contactors are used for remotely connecting and disconnecting circuits, as well as frequently starting and controlling AC motors. They can also form electromagnetic starters together with various protection devices.Due to their longer service life, higher reliability, and auxiliary switches compatible with electronic equipment, low-voltage vacuum contactors can fully replace traditional air AC contactors. They are applied in important scenarios across sectors
Echo
09/09/2025
A hybrid DC circuit breaker
Most DC molded-case circuit breakers use natural air arc extinction, and there are typically two arc extinguishing methods: one is conventional opening and closing, where the contacts axially stretch the arc, while the conductive circuit generates a magnetic field that bends and elongates the arc, pulling it lengthwise perpendicular to the arc axis. This not only increases the arc length but also induces lateral motion, enabling air cooling to achieve arc extinction.The other method involves the
Echo
09/02/2025
Seed Inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.