Type of control system

Encyclopedia
Field: Encyclopedia
0
China

Control Systems Overview


A control system is a device or set of devices that manage and regulate the behavior of other devices to achieve desired results.



6e65a5bf-2c19-4f95-8fab-81a88b6297a3.jpg


 

Linear Systems


Linear control systems adhere to principles of homogeneity and additivity, ensuring consistent and proportional responses.


 

Non-Linear Systems


Non-linear control systems do not follow linear rules, often resulting in behavior that varies significantly with different inputs.


 

67df8d9c-77d6-4d9e-9b14-0abc3a66bf0c.jpg

 

Digital vs Analog


Digital systems provide improved accuracy, reliability, and efficiency over analog systems, especially in handling non-linear control systems.


 

 

Single Input Single Output Systems


These are also known as SISO type of system. In this, the system has single input for a single output. Various example of this kind of system may include temperature control, position control system, etc.


 

Multiple Input Multiple Output Systems


Known as MIMO systems, these have multiple outputs for multiple inputs. Examples include Programmable Logic Controllers (PLC) among others.


 

Lumped Parameter System


In these types of control systems, the various active and passive components are assumed to be concentrated at a point and that’s why these are called lumped parameter type of system. Analysis of such type of system is very easy which includes differential equations.


 

Distributed Parameter System


In these types of control systems, the various active (like inductors and capacitors) and passive parameters (resistor) are assumed to be distributed uniformly along the length and that’s why these are called distributed parameter type of system. Analysis of such type of system is slightly difficult which includes partial differential equations.


Give a tip and encourage the author!

Recommended

Classification of Equipment Defects for Relay Protection and Safety Automatic Devices in Substations
In daily operations, various equipment defects are inevitably encountered. Whether maintenance personnel, operation and maintenance staff, or specialized management personnel, all must understand the defect classification system and adopt appropriate measures according to different situations.According to Q/GDW 11024-2013 "Operation and Management Guide for Relay Protection and Safety Automatic Devices in Smart Substations," equipment defects are classified into three levels based on severity an
12/15/2025
Under What Conditions Will the Line Circuit Breaker Auto-Reclosing Signal Be Locked Out?
The line circuit breaker auto-reclosing signal will be locked out if any of the following conditions occur:(1) Low SF6 gas pressure in circuit breaker chamber at 0.5MPa(2) Insufficient energy storage in circuit breaker operating mechanism or low oil pressure at 30MPa(3) Busbar protection operation(4) Circuit breaker failure protection operation(5) Line distance protection zone II or zone III operation(6) Short lead protection operation of circuit breaker(7) Presence of remote tripping signal(8)
12/15/2025
Application of Auto-Reclosing Residual Current Protective Devices in Lightning Protection for Communication Power Supplies
1. Power Interruption Problems Caused by RCD False Tripping During Lightning StrikesA typical communication power supply circuit is shown in Figure 1. A residual current device (RCD) is installed at the power supply input terminal. The RCD primarily provides protection against electrical equipment leakage currents to ensure personal safety, while surge protective devices (SPDs) are installed on power supply branches to protect against lightning intrusions. When lightning strikes occur, the senso
12/15/2025
Reclosing Charge Time: Why Does Reclosing Require Charging? What Effects Does Charging Time Have?
1. Function and Significance of Reclosing ChargingReclosing is a protective measure in power systems. After faults such as short circuits or circuit overloads occur, the system isolates the faulty circuit and then restores normal operation through reclosing. The function of reclosing is to ensure continuous operation of the power system, improving its reliability and safety.Before performing reclosing, the circuit breaker must be charged. For high-voltage circuit breakers, the charging time is g
12/15/2025