Indoor Substation

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

An indoor substation refers to a type of substation where all apparatus is installed within the substation building. Typically, this kind of substation is designed for voltages up to 11,000 volts. However, in environments where the surrounding air is contaminated by substances such as metal - corroding gases, fumes, and conductive dust, its applicable voltage range can be extended to 33,000 to 66,000 volts.

As illustrated in the diagram below, an indoor substation is divided into multiple compartments. These include the control compartment, the compartment housing indicating and metering instruments as well as protective devices, the main bus - bar compartment, and the compartment for current transformers and cable sealing boxes. Each compartment serves a specific function, ensuring the efficient and safe operation of the substation.

An indoor substation is defined as a facility where all electrical apparatus is housed within an enclosed building structure. Generally, these substations are suitable for applications with voltage levels of up to 11,000 volts. However, when situated in environments laden with contaminants like metal - corroding gases, hazardous fumes, or conductive dust particles, their operational voltage can be elevated to a range of 33,000 to 66,000 volts, enabling them to withstand harsher conditions while maintaining functionality.

substation.jpg

A general view of a unit-type metal-clad switchboard assembled of several metal-clad cubicles is shown above.


Give a tip and encourage the author!
Recommended
What should be noted when installing a Type K thermocouple?
What should be noted when installing a Type K thermocouple?
Installation precautions for Type K thermocouples are critical to ensuring measurement accuracy and extending service life. Below is an introduction to the installation guidelines for Type K thermocouples, compiled from highly authoritative sources:1.Selection and Inspection Select the appropriate thermocouple type: Choose the right thermocouple based on the temperature range, medium properties, and required accuracy of the measurement environment. Type K thermocouples are suitable for temperatu
James
11/06/2025
Essential Rules for 3-Level Electrical Distribution
Essential Rules for 3-Level Electrical Distribution
Essential Rules for Three-Level Power Distribution System Design1.Hierarchical and Branch Circuit Distribution(1) Power distribution from the primary main distribution board (distribution cabinet) to secondary distribution boards can be branched; that is, one main distribution board may supply power via multiple branch circuits to several secondary distribution boards.(2) Similarly, power distribution from a secondary distribution board to tertiary switch boxes can also be branched; that is, one
Dyson
11/06/2025
 Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes of Fire and Explosion in Oil Circuit Breakers When the oil level in an oil circuit breaker is too low, the oil layer covering the contacts becomes too thin. Under the effect of the electric arc, the oil decomposes and releases flammable gases. These gases accumulate in the space beneath the top cover, mixing with air to form an explosive mixture, which can ignite or explode under high temperature. If the oil level inside the tank is too high, the released gases have limited space to expan
Felix Spark
11/06/2025
What are the technical measures for loss reduction and energy saving in distribution systems?
What are the technical measures for loss reduction and energy saving in distribution systems?
1.Reasonable Use of TransformersTransformers should be selected with flexible winding configurations according to the power consumption characteristics of industrial enterprises, and load adjustments should be made promptly based on each transformer’s load rate to ensure operation at optimal loading conditions. Three-phase loads on transformers should be kept as balanced as possible; unbalanced operation not only reduces output capacity but also increases losses. Energy-efficient transformers sh
Echo
11/06/2025