Is it more or less dangerous to touch high voltage wires in water?

Encyclopedia
Field: Encyclopedia
0
China

Touching a high-voltage wire while in the water is indeed more dangerous.

Here's an explanation

  1. Enhanced Conductivity: Water is an excellent conductor of electricity, especially when it contains impurities such as salt water or sewage. When a person is in the water, the conductivity of the body significantly increases, which means that current can more easily pass through the human body.

  2. Reduced Insulation: In water, the insulation provided by human skin and clothing is significantly diminished. Even if high-voltage wires are not directly touched, due to the conductivity of water, current can still be transmitted through the water to the body, resulting in electrocution.

  3. Increased Rescue Difficulty: If someone is electrocuted in the water, the rescue work becomes even more challenging. Rescue personnel need to take additional safety measures, such as using insulated tools or wearing insulating equipment, to avoid being electrocuted themselves.

  4. Electric Shock Hazard Expansion: In water, current can not only spread through direct contact but also disperse through the body of water. This means that even without direct contact with high-voltage wires, one may still be affected by electric shock as long as they are within a certain range.

In summary, touching a high-voltage wire in water is more dangerous than doing so in a dry environment. Therefore, it is advisable to avoid engaging in activities in bodies of water with high-voltage wires under any circumstances.


Give a tip and encourage the author!

Recommended

Classification of Equipment Defects for Relay Protection and Safety Automatic Devices in Substations
In daily operations, various equipment defects are inevitably encountered. Whether maintenance personnel, operation and maintenance staff, or specialized management personnel, all must understand the defect classification system and adopt appropriate measures according to different situations.According to Q/GDW 11024-2013 "Operation and Management Guide for Relay Protection and Safety Automatic Devices in Smart Substations," equipment defects are classified into three levels based on severity an
12/15/2025
Under What Conditions Will the Line Circuit Breaker Auto-Reclosing Signal Be Locked Out?
The line circuit breaker auto-reclosing signal will be locked out if any of the following conditions occur:(1) Low SF6 gas pressure in circuit breaker chamber at 0.5MPa(2) Insufficient energy storage in circuit breaker operating mechanism or low oil pressure at 30MPa(3) Busbar protection operation(4) Circuit breaker failure protection operation(5) Line distance protection zone II or zone III operation(6) Short lead protection operation of circuit breaker(7) Presence of remote tripping signal(8)
12/15/2025
Application of Auto-Reclosing Residual Current Protective Devices in Lightning Protection for Communication Power Supplies
1. Power Interruption Problems Caused by RCD False Tripping During Lightning StrikesA typical communication power supply circuit is shown in Figure 1. A residual current device (RCD) is installed at the power supply input terminal. The RCD primarily provides protection against electrical equipment leakage currents to ensure personal safety, while surge protective devices (SPDs) are installed on power supply branches to protect against lightning intrusions. When lightning strikes occur, the senso
12/15/2025
Reclosing Charge Time: Why Does Reclosing Require Charging? What Effects Does Charging Time Have?
1. Function and Significance of Reclosing ChargingReclosing is a protective measure in power systems. After faults such as short circuits or circuit overloads occur, the system isolates the faulty circuit and then restores normal operation through reclosing. The function of reclosing is to ensure continuous operation of the power system, improving its reliability and safety.Before performing reclosing, the circuit breaker must be charged. For high-voltage circuit breakers, the charging time is g