How do temperature changes affect transformer performance?

Encyclopedia
Field: Encyclopedia
0
China

Impact of Temperature Changes on Transformer Performance

The influence of temperature changes on transformer performance is mainly reflected in the following aspects:

Insulation Material Aging

  • High Temperature: High temperatures accelerate the aging of internal insulation materials in transformers, reducing their insulating properties and increasing the risk of faults.

  • Low Temperature: Low temperatures can make insulation materials brittle, leading to cracks, which also affects insulation effectiveness.

Winding Resistance Changes

  • Temperature Increase: Rising temperatures cause an increase in winding resistance, leading to higher copper losses and reduced transformer efficiency.

  • Temperature Decrease: Lower temperatures reduce winding resistance, decreasing copper losses. However, low temperatures may affect the mechanical properties of materials.

Oil Temperature Changes

  • High Oil Temperature: Excessively high oil temperatures accelerate oil oxidation, reducing its insulating and cooling properties.

  • Low Oil Temperature: Very low oil temperatures increase oil viscosity, affecting oil flowability and cooling efficiency.

Load Capacity

  • High Temperature Environment: In high-temperature environments, the load capacity of transformers decreases because overheating must be avoided to prevent damage.

  • Low Temperature Environment: In low-temperature environments, the load capacity of transformers may improve slightly, but attention must still be paid to mechanical strength issues.

Thermal Expansion and Mechanical Stress

  • Temperature fluctuations cause thermal expansion and contraction of materials inside the transformer, potentially increasing mechanical stress and affecting structural stability.

Cooling System Efficiency

  • High Temperature: In high-temperature environments, the efficiency of cooling systems may decrease, making it difficult to effectively dissipate heat.

  • Low Temperature: In low-temperature environments, cooling systems may overcool, resulting in excessively low oil temperatures.

Lifespan Reduction

  • Prolonged exposure to high or low temperatures can shorten the overall lifespan of transformers and increase maintenance costs.

Therefore, properly controlling the operating temperature of transformers and ensuring they operate within design parameters is crucial for maintaining transformer performance and extending their service life.

Give a tip and encourage the author!

Recommended

Classification of Equipment Defects for Relay Protection and Safety Automatic Devices in Substations
In daily operations, various equipment defects are inevitably encountered. Whether maintenance personnel, operation and maintenance staff, or specialized management personnel, all must understand the defect classification system and adopt appropriate measures according to different situations.According to Q/GDW 11024-2013 "Operation and Management Guide for Relay Protection and Safety Automatic Devices in Smart Substations," equipment defects are classified into three levels based on severity an
12/15/2025
Under What Conditions Will the Line Circuit Breaker Auto-Reclosing Signal Be Locked Out?
The line circuit breaker auto-reclosing signal will be locked out if any of the following conditions occur:(1) Low SF6 gas pressure in circuit breaker chamber at 0.5MPa(2) Insufficient energy storage in circuit breaker operating mechanism or low oil pressure at 30MPa(3) Busbar protection operation(4) Circuit breaker failure protection operation(5) Line distance protection zone II or zone III operation(6) Short lead protection operation of circuit breaker(7) Presence of remote tripping signal(8)
12/15/2025
Application of Auto-Reclosing Residual Current Protective Devices in Lightning Protection for Communication Power Supplies
1. Power Interruption Problems Caused by RCD False Tripping During Lightning StrikesA typical communication power supply circuit is shown in Figure 1. A residual current device (RCD) is installed at the power supply input terminal. The RCD primarily provides protection against electrical equipment leakage currents to ensure personal safety, while surge protective devices (SPDs) are installed on power supply branches to protect against lightning intrusions. When lightning strikes occur, the senso
12/15/2025
Reclosing Charge Time: Why Does Reclosing Require Charging? What Effects Does Charging Time Have?
1. Function and Significance of Reclosing ChargingReclosing is a protective measure in power systems. After faults such as short circuits or circuit overloads occur, the system isolates the faulty circuit and then restores normal operation through reclosing. The function of reclosing is to ensure continuous operation of the power system, improving its reliability and safety.Before performing reclosing, the circuit breaker must be charged. For high-voltage circuit breakers, the charging time is g
12/15/2025
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.