Safety Precautions for Electrical System

Electrical4u
Electrical4u
Field: Basic Electrical
0
China

Electrical Safety Precautions

Actual safety requires whole hearted cooperation, from all levels of workers involved in the work. It is need not to say, that all the people engaged in the electrical work should well aware of all safety rules and regulations related to the work they are executing. The workers executing the work should be extremely disciplined. Electrical work should not be done by wearing loose dresses.

Before starting the work, the working place should be made neat and clean. The place should also be sufficiently illuminated before work. All levels of voltage should be considered equally dangerous. Even the voltage levels which cannot produce electrical shock should also not be ignored. We shall first confirm the circuit is dead before touching it for repairing maintenance and any others works.


    • We have to switch off, isolate and properly earth the circuit before doing any work with the circuit.

    • We shall only execute the work after getting properly issued work permit from the concerned operating personal.

    • The work permit can only be issued after making the circuit completely dead, isolated and earthed.

    • We must display Danger Board at the place of work.

    • We should not allow any unauthorized person to enter in the working place.

    • We should not put any new equipment into the service without necessary testing by authority.

    • All electrical equipments, bays, circuits, should be identified by properly viewable labels to avoid any mistake.

personal protective equipments

  • We should not work on electrical circuit during heavy lightning storm.

  • We should wear shoes having sewn soles, preferably insulated rubber soles.

  • We should not wear suspenders, arm bands, with metal buckets or other metal parts. We also do not wear metal key chain or metal keepers for key rings or watch rings outside the clothing during work. We should always, take extra precaution while work in extra damp area.

  • When there is a hurry to do the work, the tired and exhausted workers should be avoided to do so.

  • We should not toss the tools or working materials to other person. It is better to deliver the tools and materials hand to hand.

  • We should not keep any tools at the edge of equipment cabinet or structure from where these may fall off.

  • We should not do anything which may startle the person working in hazardous condition.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!
Recommended
What should be noted when installing a Type K thermocouple?
What should be noted when installing a Type K thermocouple?
Installation precautions for Type K thermocouples are critical to ensuring measurement accuracy and extending service life. Below is an introduction to the installation guidelines for Type K thermocouples, compiled from highly authoritative sources:1.Selection and Inspection Select the appropriate thermocouple type: Choose the right thermocouple based on the temperature range, medium properties, and required accuracy of the measurement environment. Type K thermocouples are suitable for temperatu
James
11/06/2025
 Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes of Fire and Explosion in Oil Circuit Breakers When the oil level in an oil circuit breaker is too low, the oil layer covering the contacts becomes too thin. Under the effect of the electric arc, the oil decomposes and releases flammable gases. These gases accumulate in the space beneath the top cover, mixing with air to form an explosive mixture, which can ignite or explode under high temperature. If the oil level inside the tank is too high, the released gases have limited space to expan
Felix Spark
11/06/2025
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Solid insulation assistance combined with dry air insulation is a development direction for 24 kV ring main units. By balancing insulation performance and compactness, the use of solid auxiliary insulation allows passing insulation tests without significantly increasing phase-to-phase or phase-to-ground dimensions. Encapsulation of the pole can address the insulation of the vacuum interrupter and its connected conductors.For the 24 kV outgoing busbar, with the phase spacing maintained at 110 mm,
Dyson
11/03/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.