What is the Radiator of Transformer?

Encyclopedia
Field: Encyclopedia
0
China

What is the Radiator of Transformer?

Radiator in Transformer Definition

A radiator in a transformer is defined as a component that helps cool the transformer by dissipating heat from the transformer oil.

bd7b3afd-a3f4-462e-9a60-6d404d41eba3.jpg

Importance of Cooling

Controlling the temperature of the oil is crucial to extend the transformer’s capacity and prevent overheating.

Working Principle

The radiator increases the surface area to dissipate heat, aiding in efficient cooling of the transformer oil.

Type of radiator

Natural air cooled radiator (ONAN) :

Without the help of any auxiliary fan, it relies only on natural convection for heat dissipation.Suitable for small transformers or load changes little, low ambient temperature occasions.

Forced Air Cooled Radiator (ONAF) :

Use a fan to speed up air flow and improve heat dissipation efficiency.Suitable for medium transformers or applications requiring rapid heat dissipation.

Water cooled Radiator (OFAF) :

Using water as cooling medium, the heat in transformer oil is taken away by water cooling pipeline.Suitable for large transformers or high ambient temperature occasions.

Forced Oil Circulation Air Cooled Radiator (ODAF) :

Combining the features of forced oil circulation and forced air cooling, oil is circulated inside and outside the transformer through the oil pump, while fans are used to accelerate the air flow.Suitable for large capacity transformers or applications requiring efficient cooling.

Operation and Enhancement

Radiators cycle warm oil from the transformer through their fins to cool it down, and this process can be boosted with fans or oil pumps.

Safety measure

Electrical isolation: Ensure electrical isolation between the radiator and the transformer body to avoid the risk of short circuit.

Grounding: The heat sink must be well grounded to prevent a fire caused by static electricity accumulation.

Matters needing attention

When performing maintenance or inspection, follow the safety operation rules to ensure the safety of personnel.For large transformers, automated monitoring and control of the cooling system may also need to be considered.

Give a tip and encourage the author!

Recommended

Classification of Equipment Defects for Relay Protection and Safety Automatic Devices in Substations
In daily operations, various equipment defects are inevitably encountered. Whether maintenance personnel, operation and maintenance staff, or specialized management personnel, all must understand the defect classification system and adopt appropriate measures according to different situations.According to Q/GDW 11024-2013 "Operation and Management Guide for Relay Protection and Safety Automatic Devices in Smart Substations," equipment defects are classified into three levels based on severity an
12/15/2025
Under What Conditions Will the Line Circuit Breaker Auto-Reclosing Signal Be Locked Out?
The line circuit breaker auto-reclosing signal will be locked out if any of the following conditions occur:(1) Low SF6 gas pressure in circuit breaker chamber at 0.5MPa(2) Insufficient energy storage in circuit breaker operating mechanism or low oil pressure at 30MPa(3) Busbar protection operation(4) Circuit breaker failure protection operation(5) Line distance protection zone II or zone III operation(6) Short lead protection operation of circuit breaker(7) Presence of remote tripping signal(8)
12/15/2025
Application of Auto-Reclosing Residual Current Protective Devices in Lightning Protection for Communication Power Supplies
1. Power Interruption Problems Caused by RCD False Tripping During Lightning StrikesA typical communication power supply circuit is shown in Figure 1. A residual current device (RCD) is installed at the power supply input terminal. The RCD primarily provides protection against electrical equipment leakage currents to ensure personal safety, while surge protective devices (SPDs) are installed on power supply branches to protect against lightning intrusions. When lightning strikes occur, the senso
12/15/2025
Reclosing Charge Time: Why Does Reclosing Require Charging? What Effects Does Charging Time Have?
1. Function and Significance of Reclosing ChargingReclosing is a protective measure in power systems. After faults such as short circuits or circuit overloads occur, the system isolates the faulty circuit and then restores normal operation through reclosing. The function of reclosing is to ensure continuous operation of the power system, improving its reliability and safety.Before performing reclosing, the circuit breaker must be charged. For high-voltage circuit breakers, the charging time is g
12/15/2025
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.