Instantaneous Relay

Electrical4u
Field: Basic Electrical
0
China

What Is An Instantaneous Relay

In a simple way electrical relay is shown in the figure above. Here the fixed coil is fed from the circuit to be protected. When there is a current in fixed coil above the pick up value, the iron plunger is so attracted, it moves upward and makes NO contact closed. The function of this relay is very fast. The normally open (NO) contacts of the relay are closed as soon as current in the fixed coil crosses the pick up value. This is a simplest example of instantaneous relay. Because ideally there is no time delay between the instant when actuating current crosses the pick up level and the instant of closing the No contacts.

Definition of Instantaneous Relay

An instantaneous relay is one in which there is no time delay provided intentionally. More specifically ideally there is no time required to operate the relay. Although there is some time delay which can not be avoided.

As the current coil is an inductor, there would be a certain delay to reach the current in the coil to its maximum value. There is also some time required for mechanical movement plunger in the relay. These time delays are inherent in the instantaneous relay but no other time delay is intentionally added. These relays can be operated in less than 0.1 sec.
instantaneous relay

Examples of Instantaneous Relays

There are various types of relay which can be considered as instantaneous relay. Such as, attracted armature relay where an iron plunger is attracted by an electromagnet to actuate the relay. When attractive force of the electromagnet crosses its pick up level, the iron plunger starts move towards the magnet and crosses the relay contacts. The magnetic strength of the electromagnet depends upon the current flows the coil conductors.

Another popular example of instantaneous relay, is solenoid type relay. When current in the solenoid crosses pick up value, the solenoid attracts an iron plunger which moves to close the relay contacts.
Balance beam relay is also an well known example of instantaneous relay. Here balance of one horizontally placed beam is disturbed due to pick up current in the relay coil. Due to unequal torques at two ends of the beam, it starts rotating against the hinge and ultimately closes the contacts of the relay.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!

Recommended

Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
01/30/2026
Neutral point grounding operation mode for 110kV~220kV power grid transformers
The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
01/29/2026
Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
01/29/2026
HECI GCB for Generators – Fast SF6 Circuit Breaker
1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
01/06/2026
Related Products
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.