What is the reason for using delta-delta connections in power transmission lines instead of other combinations?

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

Voltage Aspect

In a delta connection, the line voltage is equal to the phase voltage. This characteristic makes the delta connection widely used in high and medium voltage areas for power transmission in situations where higher voltages are required, as it can directly utilize the line voltage for power transmission without the need for additional voltage conversion operations, which helps reduce energy losses during the voltage conversion process.

For example, in a delta-connected three-phase load, each phase load is connected directly between two phase lines, and the load's phase voltage is the same as the line voltage of the power source (grid). This means that when a three-phase motor is connected in a delta configuration, each winding can withstand the line voltage (380V), whereas in a star connection, each winding of the motor bears the phase voltage (220V). For devices requiring high voltage, a delta connection is more advantageous.

Load Capacity Aspect

The increase in the number of nodes in a delta connection does not affect the power supply's load capacity, and in some cases, each winding in a delta connection has more power than the windings in a star connection, which allows the system to withstand greater loads and transmit more electrical energy in transmission lines.

The performance of triangle connection in stability compared to other connection methods

Voltage Stability

In a delta connection of three-phase power, even if one winding is short-circuited, the voltage of the other windings will not change significantly, and the voltage is relatively stable. In contrast, in a star connection, if one winding is short-circuited, the voltage of the other windings will quickly increase, which may affect the stable operation of the transmission line.

Electric Energy Balance Stability

The delta connection of a three-phase load can achieve rapid electrical energy balancing, making power transmission more stable and providing users with more efficient power supply, reducing issues such as fluctuations caused by energy imbalance.

Impact of Triangle Connection on Transmission Efficiency

Reduce line loss

Triangular connections can effectively reduce power outages, thereby indirectly improving transmission efficiency. The reduction in the number of power outages means better continuity of power supply, reducing energy losses caused by restarting equipment and readjusting power distribution due to power outages. Moreover, triangular connections can balance the load, thereby reducing losses during transmission and providing continuous and effective power services to users, improving the overall efficiency of the transmission line.

Characteristics of Triangle Connection in Fault Response

Fault Current Limiting Aspects

In a transformer delta connection, when one phase fails, the fault current will flow into the other two phases. Because this type of connection is not easy to generate residual current, in some cases, it can provide better fault current limitation compared to other connection methods. However, it should be noted that when a single-phase short circuit occurs in a delta connection, the short-circuit current can exceed many times the rated current of the capacitor, which can easily lead to the expansion of the accident.

Reliability Aspect

The delta connection of a three-phase load can prevent the system from overloading or short-circuiting, effectively improving the reliability of the power system. This is very important for transmission lines, as it can ensure the safety and stability of the transmission process, reducing issues such as transmission interruptions caused by faults.

Give a tip and encourage the author!
Recommended
What are the safety precautions and guidelines for using AC load banks?
What are the safety precautions and guidelines for using AC load banks?
AC load banks are electrical devices used to simulate real-world loads and are widely applied in power systems, communication systems, automation control systems, and other fields. To ensure personal and equipment safety during use, the following safety precautions and guidelines must be observed:Select an appropriate AC load bank: Choose an AC load bank that meets actual requirements, ensuring its capacity, voltage rating, and other parameters satisfy the intended application. Additionally, sel
Echo
11/06/2025
What should be noted when installing a Type K thermocouple?
What should be noted when installing a Type K thermocouple?
Installation precautions for Type K thermocouples are critical to ensuring measurement accuracy and extending service life. Below is an introduction to the installation guidelines for Type K thermocouples, compiled from highly authoritative sources:1.Selection and Inspection Select the appropriate thermocouple type: Choose the right thermocouple based on the temperature range, medium properties, and required accuracy of the measurement environment. Type K thermocouples are suitable for temperatu
James
11/06/2025
 Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes of Fire and Explosion in Oil Circuit Breakers When the oil level in an oil circuit breaker is too low, the oil layer covering the contacts becomes too thin. Under the effect of the electric arc, the oil decomposes and releases flammable gases. These gases accumulate in the space beneath the top cover, mixing with air to form an explosive mixture, which can ignite or explode under high temperature. If the oil level inside the tank is too high, the released gases have limited space to expan
Felix Spark
11/06/2025
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.