What Is Electrical Grid System

The connection of several generating stations in a network of particular transmission voltage level is commonly known as electrical grid system. By interconnecting different power generating stations we can solve various difficulties arise in power system. The structure, or “network topology” of a grid can vary depending on the the load and generation characteristics, constraints of budget and the requirements for system reliability. The physical layout is often forced by the geology and land availablility.

Although, forming a grid by interconnecting different generating stations located at different places is significantly expensive since the protections and operations of the entire system become more complicated. But untill modern power system demands the interconnected grid between the power stations because of its tremendous benefits against the power stations which are running individually. There are some advantages of interconnected grid system listed below one by one.

Electrical Grid System

  1. The interconnected grid increases the reliability of power system significantly. In case of failure of any generating station, the network (grid) will share the load of that generating plant. Increased reliability is the most significant advantage of a grid system.

  2. The arrangement can exchange the peak load of a plant. In case of individual operation of a generating station, if the peak load increases beyond the capacity of the generating station, we have to impose partial load shedding on the system. But when we connect the generating station to a grid system the grid carries the extra load of the station. There is no need for partial load shedding or no need for enhancement of the capacity of that particular generating station.

  3. Sometimes there are numbers of inefficient old generating stations available with a generating authority which they cannot run in continuous basis from the commercial point of view. If the entire load of the system exceeds the grid capacity, the generating authority can run these old, and inefficient plants for a short duration to meet the excess demand of the network. In this way, the authority can utilize the old and inefficient plants up to some extent without keeping them entirely idle.

  4. The grid covers a large number of consumers than that of an individual generating station. So the fluctuation of load demand of a grid is much less than that of a single generating plant. That means the load imposed on the generating station from a grid is much consistent. Depending on the consistency of the load, we can choose the installed capacity of the generating station in such a manner that the plant can run with nearly its full capacity for a significant period of time during each day. Hence the generation of electricity would be economical.

  5. The grid system can improve the diversity factor of each generating station connected to the grid. The diversity factor gets improved because the maximum demand of the grid shared by the generating station is much lesser than the maximum demand imposed on the generating station if it runs individually.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!

Recommended

Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
01/30/2026
Neutral point grounding operation mode for 110kV~220kV power grid transformers
The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
01/29/2026
Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
01/29/2026
HECI GCB for Generators – Fast SF6 Circuit Breaker
1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
01/06/2026
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.