Bundled Conductors Used in Transmission Line

Electrical4u
Field: Basic Electrical
0
China

What Are Bundled Conductors Used In Transmission Line

Single stranded conductors are used in transmission system usually up to 220 KV. But it is not possible to use single-stranded conductor for the voltage above 220 KV systems. For very high voltage system, hollow conductor can be used to optimize the flow of current through it. But erection and maintenance of hollow conductors in the ∑HV system are not economical. The problem can be solved by using bundled conductors instead of hollow conductor in the electrical transmission system above 220 KV voltage level.

What is Bundled Conductor?

We call bundled conductor to those conductors which form from two or more stranded conductors, bundled together to get more current carrying capacity.

Here, we use two or more stranded conductors per phase. Also, to increase the current carrying capacity of the system, a bundle conductor also contributes various facilities to the electrical transmission system. A bundled conductor reduces the reactance of the electric transmission line. It also reduces voltage gradient, corona loss, radio interference, surge impedance of the transmission lines.
By making bundle conductor, the geometric mean radius (GMR) of the conductor increased. As the self GMR of the conductor increases, the
inductance of the conductor decreases. Theoretically, there is an optimum sub-conductor spacing in bundle conductor that will give minimum voltage gradient on the surface of bundle conductor. The optimum spacing between sub-conductors for reducing voltage gradient is eight to ten times of the diameter of the conductor.

Since the voltage gradient gets reduced, the radio interference also gets reduced.
As the inductance of the bundled conductor is reduced, the surge impedance of the line is reduced became the formula of surge impedance is

Where L is the inductance per phase per unit length, and C is the capacitance per phase per unit length of the transmission line. As the surge impedance gets reduced due to bundling the conductor, the surge impedance loading, of the conductor gets increased. Increased surge impedance loading makes the transmission capacity of the system more.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!

Recommended

Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
01/30/2026
Neutral point grounding operation mode for 110kV~220kV power grid transformers
The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
01/29/2026
Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
01/29/2026
HECI GCB for Generators – Fast SF6 Circuit Breaker
1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
01/06/2026
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.