Power System Stability

Electrical4u
Field: Basic Electrical
0
China

What Is Power System Stability

Power system engineering forms a vast and major portion of electrical engineering studies. It is mainly concerned with the production of electrical power and its transmission from the sending end to receiving end as per requirements, incurring a minimum amount of losses. The power often changes due to the variation of load or due to disturbances.

For these reasons, the term power system stability is of utmost importance in this field. It is used to define the ability of the system to bring back its operation to steady state condition within a minimum possible time after having undergone any transience or disturbance. Ever since the 20th century, till the recent times, all major power generating stations over the globe has mainly relied on AC system as the most effective and economical option for generation and transmission of electrical power.

In power plants, several synchronous generators are connected to the bus having the same frequency and phase sequence as the generators. Therefore, for a stable operation, we have to synchronize the bus with the generators over the entire duration of generation and transmission. For this reason, the power system stability is also referred to as synchronous stability and is defined as the ability of the system to return to synchronism after having undergone some disturbance due to switching on and off of load or due to line transience. To understand, stability well, another factor needs to be considered, and that is the stability limit of the system. The stability limit defines the maximum power permissible to flow through a particular part of the system for which it is subjected to line disturbances or faulty flow of power. Having understood these terminologies related to power system stability let us now look into the different types of stability.

The power system stability or synchronous stability of a power system can be of several types depending upon the nature of the disturbance, and for successful analysis, it can be classified into the following three types as shown below:

  • Steady state stability.

  • Transient stability.

  • Dynamic stability.

power system stabilitySteady State Stability of a Power System

The steady-state stability of a power system is defined as the ability of the system to bring itself back to its stable configuration following a small disturbance in the network (like normal load fluctuation or action of automatic voltage regulator). It can only be considered only during a very gradual and infinitesimally small power change.

In case the power flow through the circuit exceeds the maximum power permissible, then there are chances that a particular machine or a group of machines will cease to operate in synchronism, and result in yet more disturbances. In such a situation, the steady-state limit of the system is said to have reached, or in other words, the steady state stability limit of a system refers to the maximum amount of power that is permissible through the system without loss of its steady state stability.

Transient Stability of a Power System

Transient stability of a power system refers to the ability of the system to reach a stable condition following a large disturbance in the network condition. In all cases related to large changes in the system like sudden application or removal of the load, switching operations, line faults or loss due to excitation the transient stability of the system comes into play. It in fact deals in the ability of the system to retain synchronism following a disturbance sustaining for a reasonably long period. And the maximum power that is permissible to flow through the network without loss of stability following a sustained period of disturbance is referred to as the transient stability of the system. Going beyond that maximum permissible value for power flow, the system would temporarily be rendered as unstable.

Dynamic Stability of a Power System

Dynamic stability of a system denotes the artificial stability given to an inherently unstable system by automatically controlled means. It is concerned to small disturbances lasting for about 10 to 30 seconds.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!

Recommended

Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
01/30/2026
Neutral point grounding operation mode for 110kV~220kV power grid transformers
The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
01/29/2026
Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
01/29/2026
HECI GCB for Generators – Fast SF6 Circuit Breaker
1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c