Advantages of using stranded conductors instead of solid conductors in electrical wiring circuits

Encyclopedia
Field: Encyclopedia
0
China

Using stranded conductors instead of solid conductors in electrical wiring circuits has the following benefits:


Mechanical properties


Better flexibility


A stranded conductor consists of strands of thin wire twisted together and is softer than a solid conductor. This makes it easier to bend and install during the wiring process, especially if you need to bypass obstacles or wire in tight Spaces.


For example, in some complex electrical control cabinets, the use of stranded conductors can easily arrange the wires in different positions without damaging the conductors due to excessive bending.


Strong tensile resistance


Because the stranded conductor is composed of multiple strands of wire, each strand of wire can share the tension when it is subjected to tension, thus improving the tensile resistance of the conductor. In contrast, solid conductors tend to break when subjected to tension.


For example, in some equipment that needs to be moved frequently or subjected to vibration, such as cranes, elevators, etc., the use of stranded conductors can better withstand mechanical stress and reduce the risk of wire breakage.


Good resistance to bending fatigue


In the case of repeated bending, the life of a stranded conductor is usually longer than that of a solid conductor. This is because the strands of the stranded conductor can slide relative when bending, thus dispersing the bending stress and reducing the fatigue damage of the conductor.


For example, in some wire applications that require frequent bending, such as mobile electrical equipment, robots, etc., the use of stranded conductors can improve the reliability and service life of the wire.


Electrical performance


Large surface area, good heat dissipation


The surface area of the stranded conductor is relatively large, which is conducive to heat dissipation. Under a high current load, the heat generated by the conductor can be dissipated more quickly, thereby reducing the temperature of the conductor and improving the safety and reliability of the electrical system.


For example, in some high-power electrical equipment, such as motors, transformers, etc., the use of stranded conductors can effectively reduce the temperature rise of conductors and avoid damage to insulation materials due to overheating.


Good high frequency characteristic


In high frequency circuits, the skin effect of the stranded conductor is relatively small, and the current is more evenly distributed across the cross section of the conductor. This makes the stranded conductor have less resistance at high frequencies and better signal transmission performance.


For example, in high frequency applications such as communications equipment and RF circuits, the use of stranded conductors can reduce signal attenuation and distortion and improve circuit performance.


Strong anti-interference ability


Stranded conductors can effectively reduce electromagnetic interference (EMI) and radio frequency interference (RFI). Because there are certain capacitors and inductors between the strands of the stranded conductor, these capacitors and inductors can form a low-pass filter, which can inhibit the high-frequency interference signal.


For example, in some electronic equipment with high electromagnetic compatibility requirements, such as computers, medical equipment, etc., the use of stranded conductors can improve the anti-interference ability of the equipment to ensure the normal operation of the equipment.


Cost aspect


The cost is relatively low


In some cases, a stranded conductor may cost less than a solid conductor. This is because stranded conductors can be twisted using thinner wires, which are generally easier to produce and process than thick solid conductors, and are relatively inexpensive.


For example, in some large-scale electrical wiring projects, the use of stranded conductors can reduce material costs and improve the economic efficiency of the project.


Sum up


Using stranded conductors instead of solid conductors in electrical wiring circuits has many benefits, including better mechanical properties, electrical performance, and cost effectiveness. In practical applications, the appropriate conductor type should be selected according to the specific needs and situations.


Give a tip and encourage the author!

Recommended

Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
01/30/2026
Classification of Equipment Defects for Relay Protection and Safety Automatic Devices in Substations
In daily operations, various equipment defects are inevitably encountered. Whether maintenance personnel, operation and maintenance staff, or specialized management personnel, all must understand the defect classification system and adopt appropriate measures according to different situations.According to Q/GDW 11024-2013 "Operation and Management Guide for Relay Protection and Safety Automatic Devices in Smart Substations," equipment defects are classified into three levels based on severity an
12/15/2025
Under What Conditions Will the Line Circuit Breaker Auto-Reclosing Signal Be Locked Out?
The line circuit breaker auto-reclosing signal will be locked out if any of the following conditions occur:(1) Low SF6 gas pressure in circuit breaker chamber at 0.5MPa(2) Insufficient energy storage in circuit breaker operating mechanism or low oil pressure at 30MPa(3) Busbar protection operation(4) Circuit breaker failure protection operation(5) Line distance protection zone II or zone III operation(6) Short lead protection operation of circuit breaker(7) Presence of remote tripping signal(8)
12/15/2025
Application of Auto-Reclosing Residual Current Protective Devices in Lightning Protection for Communication Power Supplies
1. Power Interruption Problems Caused by RCD False Tripping During Lightning StrikesA typical communication power supply circuit is shown in Figure 1. A residual current device (RCD) is installed at the power supply input terminal. The RCD primarily provides protection against electrical equipment leakage currents to ensure personal safety, while surge protective devices (SPDs) are installed on power supply branches to protect against lightning intrusions. When lightning strikes occur, the senso
12/15/2025
Related Products
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.