High Voltage Direct Current Transmission

Encyclopedia
Field: Encyclopedia
0
China

HVDC Transmission Definition

HVDC transmission is the method of transmitting electricity in DC form over long distances using either submarine cables or overhead lines.

 Conversion and Components

The hvdc transmission system uses rectifiers and inverters for converting AC to DC and vice versa, with components like smoothing reactors and harmonic filters to ensure stability and reduce interference.

 HVDC Transmission System

We know that AC power is generated in the generating station. This should first be converted into DC. The conversion is done with the help of rectifier. The DC power will flow through the overhead lines. At the user end, this DC has to be converted into AC. For that purpose, an inverter is placed at the receiving end.

 Thus, there will be a rectifier terminal in one end of HVDC substation and an inverter terminal in the other end. The power of the sending end and user end will be always equal (Input Power = Output Power).

56612585a6482fc8a6e1fe2e4175191a.jpeg

 When there are two converter stations at both ends and a single transmission line is termed as two terminal DC systems. When there are two or more converter stations and DC transmission lines is termed as multi-terminal DC substation.

b05cece93281b7b52cd4fc107cc27084.jpeg

 


The components of the HVDC Transmission system and its function are explained below.

Converters: The AC to DC and DC to AC conversion are done by the converters. It includes transformers and valve bridges.

Smoothing Reactors: Each pole consist of smoothing reactors which are of inductors connected in series with the pole. It is used to avoid commutation failures occurring in inverters, reduces harmonics and avoids discontinuation of current for loads.

Electrodes: They are actually conductors which are used to connect the system to the earth.

Harmonic Filters: It is used to minimize the harmonics in voltage and current of the converters used.

 DC Lines: It can be cables or overhead lines.

Reactive Power Supplies: The reactive power used by the converters could be more than 50% of the total transferred active power. So the shunt capacitors provide this reactive power.

AC Circuit Breakers: The fault in the transformer is cleared by the circuit breakers. It also used to disconnect the DC link.

Link Types

  • Mono-polar Link

  • Bipolar Link

  • Homopolar Link

 Single conductor is required and water or ground act as the return path. If the earth resistivity is high, metallic return is used.

6694f3d466b5b8b297999ad650c1ea86.jpeg

Double converters of same voltage rating are used in each terminal. The converter junctions are grounded.

 


6059612df1b17a7caa0e1143445d28a0.jpeg

 It consists of more than two conductors which is having equal polarity generally negative. Ground is the return path.


c65e1db8e24402c487da78355b59a308.jpeg

 


Multi Terminal Links

It is used to connect more than two points and is rarely used.

Comparison of both HVAC and HVDC Transmission System


6372c8f600dd33f105779d4d99362cdd.jpeg

 Efficiency Advantages

  • Converters with small overload capacity are used.

  • Circuit Breakers, Converters and AC filters are expensive especially for small distance transmission.

  • No transformers for altering the voltage level.

  • HVDC link is extremely complicated.

  • Uncontrollable power flow.

Practical Applications

  • Undersea and underground cables

  • AC network interconnections

  • Interconnecting Asynchronous system

Give a tip and encourage the author!

Recommended

Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
01/30/2026
Classification of Equipment Defects for Relay Protection and Safety Automatic Devices in Substations
In daily operations, various equipment defects are inevitably encountered. Whether maintenance personnel, operation and maintenance staff, or specialized management personnel, all must understand the defect classification system and adopt appropriate measures according to different situations.According to Q/GDW 11024-2013 "Operation and Management Guide for Relay Protection and Safety Automatic Devices in Smart Substations," equipment defects are classified into three levels based on severity an
12/15/2025
Under What Conditions Will the Line Circuit Breaker Auto-Reclosing Signal Be Locked Out?
The line circuit breaker auto-reclosing signal will be locked out if any of the following conditions occur:(1) Low SF6 gas pressure in circuit breaker chamber at 0.5MPa(2) Insufficient energy storage in circuit breaker operating mechanism or low oil pressure at 30MPa(3) Busbar protection operation(4) Circuit breaker failure protection operation(5) Line distance protection zone II or zone III operation(6) Short lead protection operation of circuit breaker(7) Presence of remote tripping signal(8)
12/15/2025
Application of Auto-Reclosing Residual Current Protective Devices in Lightning Protection for Communication Power Supplies
1. Power Interruption Problems Caused by RCD False Tripping During Lightning StrikesA typical communication power supply circuit is shown in Figure 1. A residual current device (RCD) is installed at the power supply input terminal. The RCD primarily provides protection against electrical equipment leakage currents to ensure personal safety, while surge protective devices (SPDs) are installed on power supply branches to protect against lightning intrusions. When lightning strikes occur, the senso
12/15/2025
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.