Is it necessary to adjust the wire size when the supply voltage is increased?

Encyclopedia
Field: Encyclopedia
0
China

Whether to adjust the wire diameter when the power supply voltage increases

When the supply voltage increases, the need to adjust the wire diameter depends on a number of factors, including the original design of the line, the load requirements, and the specific circumstances of the voltage increase. Here's an analysis based on search results:

Factors affecting wire diameter

Line loss problem

Too small power supply line diameter will lead to increased line resistance, increase the loss of electrical energy into heat, and thus increase the line loss ratio 1. Therefore, if the supply voltage increases resulting in an increase in current demand, the original wire diameter may not be able to effectively transmit power, and it may be necessary to consider increasing the wire diameter to reduce line loss.

Current capacity

The cross-sectional area of a wire is directly related to the current capacity it can carry. If an increase in voltage results in an increase in current while the wire diameter is unchanged, the safe current-carrying capacity of the wire may be exceeded, causing an overload or fire risk1. In this case, the wire diameter needs to be adjusted to accommodate the higher current requirements.

Supply radius

A long supply radius will increase voltage drop and resistance, which will affect line loss 1. If the voltage increases while the supply radius remains the same, it may be necessary to consider adjusting the wire diameter to reduce voltage loss.

Consideration when voltage increases

Equipment requirement

The increase in supply voltage may be because the device requires a higher voltage to operate. In this case, the wire diameter adjustment should take into account the rated voltage and current requirements of the equipment to ensure that the wire diameter can support these requirements .

Voltage regulation

The power supply voltage can be controlled using a voltage regulator, but line diameter adjustment is still important. If the voltage regulator does not fully compensate for voltage losses on the line, the line diameter may need to be adjusted .

Conclusion

In summary, when the supply voltage is increased, it is often necessary to evaluate whether the wire diameter is sufficient to support the new current demand and voltage transfer efficiency. If the original wire diameter is insufficient to meet the increased voltage and current requirements, or there is a significant line loss problem, then the adjustment of the wire diameter is necessary. However, specific operations should be carried out according to actual electrical engineering calculations and recommendations of professionals to ensure safety and efficiency.

Give a tip and encourage the author!

Recommended

Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
01/30/2026
Classification of Equipment Defects for Relay Protection and Safety Automatic Devices in Substations
In daily operations, various equipment defects are inevitably encountered. Whether maintenance personnel, operation and maintenance staff, or specialized management personnel, all must understand the defect classification system and adopt appropriate measures according to different situations.According to Q/GDW 11024-2013 "Operation and Management Guide for Relay Protection and Safety Automatic Devices in Smart Substations," equipment defects are classified into three levels based on severity an
12/15/2025
Under What Conditions Will the Line Circuit Breaker Auto-Reclosing Signal Be Locked Out?
The line circuit breaker auto-reclosing signal will be locked out if any of the following conditions occur:(1) Low SF6 gas pressure in circuit breaker chamber at 0.5MPa(2) Insufficient energy storage in circuit breaker operating mechanism or low oil pressure at 30MPa(3) Busbar protection operation(4) Circuit breaker failure protection operation(5) Line distance protection zone II or zone III operation(6) Short lead protection operation of circuit breaker(7) Presence of remote tripping signal(8)
12/15/2025
Application of Auto-Reclosing Residual Current Protective Devices in Lightning Protection for Communication Power Supplies
1. Power Interruption Problems Caused by RCD False Tripping During Lightning StrikesA typical communication power supply circuit is shown in Figure 1. A residual current device (RCD) is installed at the power supply input terminal. The RCD primarily provides protection against electrical equipment leakage currents to ensure personal safety, while surge protective devices (SPDs) are installed on power supply branches to protect against lightning intrusions. When lightning strikes occur, the senso
12/15/2025
Related Products
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.