Power electronic transformer with adaptive PLL technique for voltage-disturbance ride through

IEEE Xplore
Field: Electrical Standards
0
Canada

A novel PET for a distribution grid called a flexible power distribution unit is proposed in this paper, and the energy exchange mechanism between the network and the load is revealed.   A 30 kW 600 VAC/220 VAC/110 VDC medium-frequency isolated prototype is developed and demonstrated.   This paper also presents key control strategies of the PET for electrical distribution grid applications, especially under grid voltage disturbance conditions.   Moreover, stability issues related to the grid-connected three-phase PET are discussed and verified with an impedance-based analysis.   The PET prototype is tested, and it passes the voltage-disturbance ride-through function.   The experimental results verify the power quality control abilities of the PET.

Source: IEEE Xplore

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!
Recommended
Power electronic transformer with adaptive PLL technique for voltage-disturbance ride through
A novel PET for a distribution grid called a flexible power distribution unit is proposed in this paper, and the energy exchange mechanism between the network and the load is revealed. A 30 kW 600 VAC/220 VAC/110 VDC medium-frequency isolated prototype is developed and demonstrated. This paper also presents key control strategies of the PET for electrical distribution grid applications, especially under grid voltage disturbance conditions. Moreover, stability issues related to the grid-connec
IEEE Xplore
03/07/2024
Individual DC Voltage Balance Control for Cascaded H-Bridge Electronic Power Transformer With Separated DC-Link Topology
In this paper, an overall individual dc voltage (including high-voltage and low-voltage dc-link voltages) balance strategy is proposed for the electronic power transformer with separated dc-link topology. The strategy adjusts active powers flowing through the isolation and output stages in different power modules to enhance the dc voltage balance capability. Through the strategy, the high-voltage and low-voltage dc-links can be well balanced when unbalance occurs among different power modules
IEEE Xplore
03/07/2024
A Two-Stage DC-DC Isolated Converter for Battery-Charging Applications
This paper proposes and analyzes a two-stage dc-dc isolated converter for electric vehicle charging applications, where high efficiency over a wide range of battery voltages is required. The proposed conversion circuit comprises a first two-output isolation stage with CLLC resonant structure and a second two-input buck regulator. The transformer of the first stage is designed such that its two output voltages correspond, ideally, to the minimum and maximum expected voltage to be supplied to th
IEEE Xplore
03/07/2024
A Review of Current-Limiting Control of Grid-Forming Inverters Under Symmetrical Disturbances
Grid-forming (GFM) inverters are recognized as a viable solution to increase the penetration of renewable energy in bulk power systems. However, they are physically different from synchronous generators in terms of overcurrent capability. To protect the power semiconductor devices and support the power grid under severe symmetrical disturbances, the GFM control systems should be able to achieve the following requirements: current magnitude limitation, fault current contribution, and fault reco