Product descriptions from the supplier

Description

Product advantages
A new type of cable joint product
CMJ (Cable Melt Joint) is a technology independently developed by the company, which applies the new generation of power cable connection technology. The product has a different structural form from ordinary cold shrink, heat shrink, and prefabricated cable joints, and is a new type of cable joint product.
Strong current carrying capacity
The conductor adopts exothermic welding technology, with equal diameter, low resistance, high strength, and welding points that never age. It can withstand fault current surges and long-term high current operation, providing a durable and reliable electrical connection.
Reliable control of electric field stress
The fusion joint is made by restoring the cable conductor shielding layer and insulation shielding layer according to the original cable's conductor shielding and outer shielding structure, specifications, and the same materials, to achieve a continuous and equivalent matching cable electric field shielding body between CMJ and the original cable, so that the electric field distribution and strength are in the best natural state, highlighting the electrical stability and operational reliability of CMJ.
Good insulation performance
By using XLPE without air gap interface fusion bonding, which is the same as the cable insulation, a structure is formed that is consistent with the cable without obvious joint characteristics. The insulation strength is consistent with the original cable, and it has higher electrical insulation and stable durability performance during operation.
Equal diameter connection saves space
CMJ can be made with a diameter approximately equal to or equal to the outer diameter of the cable, and can be placed in special positions such as cable bends and high-altitude suspensions, without taking up too much space for installation.
High mechanical strength
The conductor core is welded, and the repaired cable can be bent and dragged.
good sealing performance
On site layered fusion bonding, seamless fusion bonding between the inner and outer semi conductors, insulation body and the original cable, with no interface, and good waterproof performance.

performance parameters

Test Items 10kV 20kV 35kV Test Results
Rated Voltage 8.7/15kV 12/20kV 26/35kV /
Partial Discharge Partial discharge < 10pC at 15kV Partial discharge < 10pC at 20kV Partial discharge < 10pC at 45kV Partial discharge < 1pC
Lightning Impulse Withstand Voltage 95kV, ±10 times 125kV, ±10 times 200kV, ±10 times Meet the requirements
Power Frequency Withstand Voltage 39kV for 5min 54kV for 5min 117kV for 5min Meet the requirements

Technical Specifications

Conductor Cross - Section (mm²) 10kV Fusion Joint Model  
  Single - core Three - core
25 - 50 CMJ10 - 1.1 CMJ10 - 3.1
70 - 120 CMJ10 - 1.2 CMJ10 - 3.2
150 - 240 CMJ10 - 1.3 CMJ10 - 3.3
300 - 400 CMJ10 - 1.4 CMJ10 - 3.4
500 - 630 CMJ10 - 1.5  
Conductor Cross - Section (mm²) 35kV Fusion Joint Model  
  Single - core Three - core
50 - 95 CMJ35 - 1.1 CMJ35 - 3.1
120 - 185 CMJ35 - 1.2 CMJ35 - 3.2
240 - 400 CMJ35 - 1.3 CMJ35 - 3.3
500 CMJ35 - 1.4 CMJ35 - 3.4
630 CMJ35 - 1.5  
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.