10KW ON/OFF Grid Wind Power controller

  • 10KW ON/OFF Grid Wind Power controller

Key attributes

Brand Wone Store
Model NO. 10KW ON/OFF Grid Wind Power controller
Input Voltage 380V
Power 10KW
Series WWGI

Product descriptions from the supplier

Description

Features

▪ Wind Controller &Inverter integrated machine.

▪ MPPT included, and 30-point power curve can be settable.

▪ Complete protection functions.

▪ RS485 monitoring mode optional.

Applications

▪ Distributed wind power grid-tied system.

▪ Solar &wind hybrid power grid-tied system.

▪ Wind power grid-tied system.

 

Technical Parameters                                                                                                                                                                                                  

Model

WWGI100

Wind Turbine Input

Rated input power

10kW

Max. input power

15kW

Rated input voltage

380VDC

Rated input current

15.2A

Max input current

22.8A

Cutting speed

60RPM(factory default)

Power tracking

30 points set power curve

Speed limit control

Electromagnetic speed limit

Manual brake

YES

Brake by overcurrent

YES

Brake by over rotational Speed

YES

Brake by over wind speed

optional

AC Output

Grid Type

Three-phase

Rated output power

10kW

Max output power

11kW

Rated Grid voltage

380VAC

Grid voltage range

85%~110% of rated grid voltage

Rated Grid frequency

50Hz/60Hz

Work frequency range

49Hz~51Hz/59Hz~61Hz

Rated output current

4.6A

Rated power factor

>0.98

Thdi

<5% (at rated power)

DC component

<0.5%

soft start

Yes

Restoring grid-connected functionality

Yes

Auto on/off

Yes

Protection Functions

Grid overvoltage/undervoltage protection

Yes

Grid over frequency/under frequency protection

Yes

output short circuit protection

Yes

Grid power failure protection

Yes

Anti-islanding protection

Yes

Over-temperature protection

Yes

Lightning protection

Yes

Residual current protection

Yes

General Parameters

Display mode

LED+LCD

Display information

Display: wind Voltage, Wind current,Wind power, Wind Speed, Pole Paris; Inverter voltage, Inverter current, Inverter Power, Inverter Frequency, Relay Time, power generation; BUS Voltage, Air speed, Temperature, Time, Language, ID, etc.

Status: Manual brake, automatic brake, fault indication, grid-connected state, relay state, Wind cut-in, etc.

Monitoring mode(optional)

RS485/WIFI

Monitoring contents

Telemetry: wind turbine speed, Inverter voltage, Inverter current, Inverter power, power generation,Air speed;

Remote signal: wind turbine status, wind power grid-connected inverter over-current alarm, over-voltage alarm, over-temperature alarm, fault alarm, etc.;

Remote control: modify the parameters of the wind power

Efficiency

>95%

Ambient temperature

-20℃~+40℃

Humidity

0%~90%, no condensing

Vibration resistance

Can withstand sine wave vibration with a frequency of 10Hz~50Hz and an amplitude of 0.35mm

Noise

≤65dB

Cooling mode

Air-cooled

Note: Part of parameters can be adjusted according to customer's specific demand.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings/Instrument Transformer/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Dedicated Vacuum Contactor Solution for Port Shore Power Systems
    I. Background and Challenges​Shore power systems have become core technical equipment for ports to reduce carbon emissions and noise pollution. However, these systems face two major challenges in the harsh operational environment of ports:​Severe Environmental Corrosion: High humidity and salt spray in port areas cause serious corrosion to metal components and enclosures of electrical equipment, significantly impacting electrical lifespan and operational reliability.​High Switching Requirements:
    09/13/2025
  • ABB Vacuum Contactor KC2 Power Supply System Technical Transformation Plan
    Issue Overview​The 10kV air compressor starting system of a company utilizes the ABB vacuum contactor KC2 as the control component for the operating circuit. The dedicated wide-voltage power supply module paired with this contactor presents the following issues:​Frequent failures: The power supply module fails to properly transition the voltage from 300V to 12V, resulting in fuse blowouts.​Poor heat dissipation: Enclosed installation of the module leads to insufficient heat dissipation, acceler
    09/13/2025
  • Solution for Medium-Voltage Motor Control and Protection Using Vacuum Contactor-Fuse (VCF) in a Coal Conveying System
    1.Project BackgroundA coal conveying system comprises 15 belt conveyors driven by medium-voltage motors. The system operates under complex conditions, with motors often subjected to heavy loads and frequent starts. To address these challenges and achieve effective control and reliable protection during motor startup, the project comprehensively adopts Vacuum Contactor-Fuse (VCF) combination devices for the 6kV medium-voltage motor power distribution. This solution details the technical features,
    09/13/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.