11.5kV 13.2kV 14.4kV 17.5kV SF₆ gas-free ring main unit /switchgear source manufacturer

  • 11.5kV 13.2kV 14.4kV 17.5kV SF₆ gas-free ring main unit /switchgear source manufacturer

Key attributes

Brand ABB
Model NO. 11.5kV 13.2kV 14.4kV 17.5kV SF₆ gas-free ring main unit /switchgear source manufacturer
Rated voltage 24kV
Rated frequency 50/60Hz
Series UniSec Air

Product descriptions from the supplier

Description

Description:

UniSec Air is a medium voltage switchgear designed for secondary distribution up to 24kV, 630A, 20kA. It contains GSec Air, three-position load break switch or disconnector and earthing switch. This new component has a shunt vacuum interrupter for breaking capacity, dry air as the insulation medium, and a global warming potential (GWP) of zero. The switchgear also contains a vacuum circuit breaker and is fully compliant with IEC standards and the U F-gas regulation (EU) 2024 / 573. 
The switchgear is based on a highly flexible and modular  concept with standardized solutions that can be  readily configured to meet the specific needs of each application. UniSec Air is fully tested according to IEC standard 62271-200. 
UniSec Air is internal arc classified, IAC A FLR up to 20 kA, assuring safe operations for technicians when standing in  front of the switchgear. Robust control and protection, metering, monitoring, and diagnostics suitable for various applications are also available. 
UniSec Air is designed with a refined interface and with  the same footprint, operations, and backward compatibility as the original UniSec switchgear,facilitating integration into existing systems and extensions of the installed base.

Customer benefits:

F-gas regulation compliance 

  • Fully compliant with the EU F-gas regulation (EU) 2024 / 573

  • GWP of 0

Flexible and modular design

  • Better accessibility to MV cable connection and simplified installation, use, and maintenance.

  • Wide range of functional units equipped with LBS and disconnector, circuit breaker, conventional measuring transformers, current and voltage sensors, and protection relay solutions, making it suitable for most indoor applications.

  • Provides flexibility for a high level of customization to meet demanding requirements and is easy to order thanks to user-friendly configurator tools.

  • Compact design with multiple functional units width 375, 500 and 750mm for installation in a wide variety of electrial rooms and layouts.

  • Backward compatibility between UniSec Air and UniSec allows for easy integration into existing systems and extensions of the installed base.

 Safe and Reliable

  •  Internal arc classification available with various gas exhaust variants  for enhanced safety.

  • Service continuity solutions LSC2B / LSC2A / LSC2 tailored for application needs, ensuring minimal service interruption.

  • High operator safety features an internal arc-proof design and a wide range of mechanical and electrical interlocks to enhance operator safety.

  • The GSec Air component has an internal volume of less than 25 liters.

  • Fast and dependable delivery times with pre-engineered just to install (JTI) switchgear solutions.

Main Technical Characteristics:

The voltage classes of some of these eco-friendly switchgears include 6kV, 6.3kV, 6.6kV, 6.9kV, 7.2kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV, 13.2kV, 13.8kV, 14.5kV, 14.4kV, 15kV, 15.5kV, 15.6kV, 17.5kV, 20kV, 21.9kV, 22kV, 24kV, 30kV, 33kV, 33.5kV, 34.5kV, 35kV, 36kV, 38kV, 38.5kV, 40.5kV, 44kV, 45kV, 46kV, 66kV and 69kV. and customization is available.

 GSec Air:

 

Documentation Resource Library
Public.
SF6-free air-insulated switchgear for secondary distribution
Catalogue
English
FAQ for
Q: What standards and certifications that ABB’s medium voltage switchgear products comply with?
A: Our medium voltage switchgear products comply with international standards such as IEC 62271, GOST, GB/DL. They are also certified by leading industry bodies to ensure the highest levels of safety and performance. ABB also offers medium voltage switchgear products for ANSI standards.
Q: What’s the difference in the circuit breaker for air-insulated vs gas-insulated?
A: Air-insulated switchgear circuit breaker is typically removable or withdrawable. The circuit breaker is based on vacuum circuit technology. In the gas-insulated, it is fixed mounted. The function of withdraw is provided by a separate disconnecting switch. Typically, a three-position switch with connected, disconnected, and ready-to-earth position.
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 20000m² Total staff: Highest Annual Export(usD): 580000000
Workplace: 20000m²
Total staff:
Highest Annual Export(usD): 580000000
Services
Business Type: Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Comparative Analysis of High-Voltage Load Switch Technologies
    A load switch is a type of switching device positioned between circuit breakers and disconnectors. It features a simple arc extinguishing device capable of interrupting rated load current and certain overload currents, but cannot interrupt short-circuit currents. Load switches can be classified into high-voltage and low-voltage types according to their operating voltage.Solid gas-producing high-voltage load switch: This type utilizes the energy from the breaking arc itself to cause gas-producing
    12/15/2025
  • Analysis of Faults and Solutions for 17.5kV Ring Main Units in Distribution Networks
    With the improvement of social productivity and people's quality of life, the demand for electricity is continuously increasing. To ensure the effectiveness of power grid system configuration, it is necessary to reasonably construct distribution networks based on actual conditions. However, during the operation of distribution network systems, 17.5kV ring main units play a very important role, so the impact caused by failures is extremely significant. At this point, it is essential to adopt reas
    12/11/2025
  • How to install a DTU on an N2 Insulation ring main unit?
    DTU (Distribution Terminal Unit), a substation terminal in distribution automation systems, is secondary equipment installed in switching stations, distribution rooms, N2 Insulation ring main units (RMUs), and box-type substations. It bridges primary equipment and the distribution automation master station. Older N2 Insulation RMUs without DTUs cannot communicate with the master station, failing to meet automation requirements. While replacing entire RMUs with new DTU-integrated models would sol
    12/11/2025
  • Design of a New 12kV Environmentally Friendly Gas-Insulated Ring Main Unit
    1. Specific Design1.1 Design ConceptState Grid Corporation of China actively promotes grid energy conservation and low-carbon development to achieve national carbon peak (2030) and neutrality (2060) goals. Environmentally friendly gas-insulated ring main units represent this trend. A new 12kV integrated environmentally friendly gas-insulated ring main unit was designed combining vacuum interrupter technology with three-position disconnectors and vacuum circuit breakers. The design utilized Solid
    12/11/2025
  • Integrated Intelligent Ring Main Units in 10kV Distribution Automation
    In the rational application of intelligent technologies, the integrated intelligent ring main unit in 10kV distribution automation construction is more conducive to improving the construction level of 10kV distribution automation and ensuring the stability of 10kV distribution automation construction.1 Research Background Integrated intelligent ring main unit.(1) The integrated intelligent ring main unit adopts more advanced technologies, including but not limited to network technology, communic
    12/10/2025
  • 35kV RMU Busbar Failure Due to Installation Errors Analysis
    This article introduces a case of 35kV ring main unit busbar insulation breakdown failure, analyzes the failure causes and proposes solutions [3], providing reference for the construction and operation of new energy power stations.1 Accident OverviewOn March 17, 2023, a photovoltaic desertification control project site reported a ground fault trip accident in the 35kV ring main unit [4]. The equipment manufacturer arranged a team of technical experts to rush to the site to investigate the cause
    12/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.