• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


11kV 12kV 35kVSF6 gas-insulated box-type Ring Main Unit/closed switchgear

  • 11kV 12kV 35kVSF6 gas-insulated box-type Ring Main Unit/closed switchgear
  • 11kV 12kV 35kVSF6 gas-insulated box-type Ring Main Unit/closed switchgear

Key attributes

Brand ROCKWILL
Model NO. 11kV 12kV 35kVSF6 gas-insulated box-type Ring Main Unit/closed switchgear
Rated frequency 50/60Hz
Series RMU

Product descriptions from the supplier

Description
Description

SF6 ring main unit has the advantages of compact structure, fully enclosed type, fully insulated layer, long service life, maintenance-free, small indoor space occupation, and no environmental hazards during work. Widely used in industrial production and civil cable ring network and power supply system. It is very suitable for small and medium secondary substations, opening and closing stations, factories and mines, airports, railway lines, residential quarters, multi-storey buildings, highways, subway stations, tunnel construction and other industries.

Working environment conditions

  • Applicable altitude: 1000m
  • Applicable temperature: -40ºC~+45ºC
  • Relative humidity: daily average ≤95%, monthly average ≤90%
  • Earthquake damage level: ≤8

Structural features

  • Safe and reliable operation: Through multiple safety protection designs (such as a comprehensive interlocking mechanism and overload protection), it fully ensures the safety of the equipment during operation and running, effectively avoiding risks such as misoperation and short circuits. It builds a solid foundation for the continuous and stable operation of the power system, ensuring the continuity and reliability of power supply.
  • Integrated three-position load switch: Adopting an integrated three-position load switch (with three working positions: closing, opening, and grounding), it not only simplifies the internal structure and operation process of the equipment but also significantly improves the accuracy, coordination, and response speed of switch actions through precise mechanical linkage design. This reduces operational errors and enhances the stability of equipment operation.
  • Strong economic efficiency and durability: Achieves maintenance-free performance with high-quality materials and sealing technology, eliminating the need for frequent shutdowns for maintenance and reducing labor and material costs. Meanwhile, the equipment has high overall reliability, excellent anti-aging and anti-corrosion properties, and a service life of up to 20 years. This significantly reduces the frequency of equipment replacement and, in the long run, greatly lowers the full-life-cycle operating costs of the project.
  • Flexible and diverse solutions: Supports multiple incoming line modes such as left, right, upper, and forward incoming lines, which can be freely selected according to the on-site space layout. Unit combinations are not restricted, enabling complex combinations such as multi-unit series and parallel connections as needed. Combined with insulated busbar connection technology, it can flexibly build layout schemes of front-rear cabinets or left-right cabinets, perfectly adapting to the installation needs of different power distribution scenarios.
  • Wide design adaptability: The design scheme balances versatility and customization needs. It can not only meet the power distribution scenarios of conventional industrial plants and commercial buildings but also adapt to high-demand power distribution environments in special fields such as new energy power stations, rail transit, and data centers. With flexible and changeable structural design, it easily copes with personalized needs such as voltage levels and load capacities in different scenarios.
  • Efficient outgoing lines and space-saving: The outgoing line circuit design has a large capacity bearing capacity, which can meet the power output needs of high-power equipment. At the same time, it adopts a compact structural layout, minimizing the floor area while ensuring performance. It is especially suitable for scenarios with tight land resources such as urban core areas and industrial parks, achieving dual optimization of efficient power distribution and space utilization.

 

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.