• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


12kV 13.2kV 36kV 38kV 40.5kV 72.5kV 145kV High Performers Dead Tank circuit breaker

  • 12kV 13.2kV 36kV 38kV 40.5kV 72.5kV 145kV High Performers Dead Tank circuit breaker

Key attributes

Brand ROCKWILL
Model NO. 12kV 13.2kV 36kV 38kV 40.5kV 72.5kV 145kV High Performers Dead Tank circuit breaker
Rated voltage 252kV
Rated normal current 4000A
Rated frequency 50/60Hz
Rated short circuit breaking current 50kA
Series LW58A

Product descriptions from the supplier

Description

Product introduction

As China's first source factory specializing in GIS tank circuit breakers, we hold a pioneering position in the industry with decades of accumulated technical experience. Leveraging advanced R&D capabilities and mature manufacturing technologies, our products are widely recognized for their market-leading reliability and performance.

LW58A-40.5/72.5/138/145/252 Dead Tank circuit breaker is a new generation of open high-voltage electrical equipment developed independently ,The tank type circuit breaker is composed of the entrance bushing, lead-out bushing, CT, arc extinguishing chamber, chassis, operating mechanism, etc. It can be used in the high-cold and high-altitude area, At present, the new generation of tank products have reached the leading domestic and international advanced level in advanced technology and quality reliability.

Main characteristic

  •  Good anti-seismic performance, the product is equivalent to the seismic grade of GlS.

    (a)Horizontal arrangement of arc extinguishing chamber, low center of gravity.

    (b)Auto seismic frequency: The porcelain column breaker is about 4.5 Hz, and the tank circuit breaker is about 13.5 Hz.

  • The electric tracing band solution can be used in the high-cold region, which can not be realized by the porcelain column circuit breaker.

  • The product can be used in an area of 5000m , the standard configuration of the arc extinguishing chamber & drive system can only be fixed with the height of the outlet casing.

  •  The tank type circuit breakers integrates the straight through current transformer, the product covers a small area the quality is stable, and the on-site maintenance work is small. At the same time, it solves the problems such as the small margin of CT insulation ,the limitation of CT capacity and the high cost ,aging, cracking and explosion of the CT.

  •  Design of an arc extinguishing chamber:Horizontal Structure, it adopts thermal expansion and auxiliary pressure gas extinguishing technology, which has small operation work, excellent breaking performance and more than 20 electrical life.

  • Environment adaptability:It is suitable for severe environment conditions (such as severe pollution, water fog, hall, etc.), high - altitude area, high altitude area, earthquake area, the box body is sealed with air bag type, and the body protection grade is lP66.

  • The CT of variable ratio and multi-level combination can be attached, high accuracy, easy to add capacity, and meet 80% or the operating frequency voltage under the value of 5Pc, can be configured with TPY.

  •  Complete CT protection measures: CT shell is sealed at both ends of the shell and has special ant-condensation design.

  • The light spring operating mechanism adopts the overall cast aluminum frame. Breaking spring , closing spring and buffer are arranged in a centralized manner, and all adopt spiral double pressure spring, compact structure, not easy to fatigue.

  • The product is small, with integrated design, integrated supply, integrated installation conditions.

  • With the breaking capacity of the 4000A back-to-back capacitor bank.

Main technical parameters

Among these, some SF6 tank circuit breakers cover non-standard voltage levels including Customizable Voltage Ratings: 3.6kV, 4.76kV, 7.2kV, 8.25kV, 11kV, 12kV, 13.2kV, 13.8kV, 15kV, 15.5kV, 17.5kV, 22kV, 22.9kV, 24kV, 25.8kV, 27kV, 33kV, 36kV, 38kV, 40.5kV, 44kV, 60kV, 63kV, 66kV, 69kV, 88kV, 115kV, 123kV, 125kV, 126kV, 132kV, 138kV, 145kV, 150kV, 170kV, 184kV, 204kV, 220kV, 225kV, 230kV, 245kV, 275kV, 330kV, 345kV, 400kV, 765kV, 800kV with a rated short-circuit breaking current of 50kA or 63kA, and we offer customization services.

NO

Name

Unit

Data

1

Rated voltage

kV

40.5

72.5

145

252

2

Operational altitude

M

≤5000

3

Operating ambient   temperature

-40~55

4

Operating pollution   class

Class

5

Wind speed resistance

m/s

34

6

Aseismatic class

 

AG5

7

1min rated power frequency 

withstand voltage   (r.m.s)

Phase to earth

kV

95

160

275

552

Across isolating distance

kV

118

160(+42)

315

552(+175.2)

8

Rated lightning impulse 

withstand voltage   (peak)

Phase to earth

kV

185

380

650

1260

Across isolating distance

kV

215

380(+59)

750

1260(+247.2)

9

Rated frequency

HZ

50

50/60

50

50/60

10

Rated current

A

2500/3150/4000

2500/3150/4000

3150

4000

11

Rated short-time withstand current (r.m.s)

kA

31.5

40

40

40

50

12

Rated short-circuit withstand time

S

4

13

Coefficient of opening   pole

 

1.5

1.3/1.5

1.3/1.5

1.3

14

Electrical life

Times

22

15

Rated SF6 gas pressure(20℃)

MPa

0.45

0.4

0.6

0.6

16

Mechanical life

Times

10K

Order Notice:

  • Model and format of circuit breaker.

  • Rated electrical parameters (voltage, current, break current, etc).

  • Working conditions for using (environment temperature, altitude, and environment pollution level).

  • Operating voltage of operating mechanism and motor voltage.

  • The number of current transformer, current ratio, class combination and secondary load.

  • Names and quantities of spare items needed, parts and special equipment and tools(to be otherwise ordered).

Documentation Resource Library
Restricted
138kV Station Switchgear Technical Specification with IEEE&ANSI
Technical Data Sheet
English
Consulting
Consulting
Restricted
138kV Station Switchgear Technical Specification with IEC
Technical Data Sheet
Chinese
Consulting
Consulting
Restricted
Dead Tank Circuit Breakers Catalog
Catalogue
English
Consulting
Consulting
FAQ
Q: What are the core differences and key selection points of SF6 tank circuit breakers with voltage levels of 138kV/145kV/252kV?
A:

145kV is a mainstream standard grade in China, 138kV is an American standard specification, and 252kV is suitable for higher-voltage scenarios. Core differences and selection points: ① Insulation and parameters — the break spacing and rated SF6 pressure (0.7MPa) of 252kV are both higher than the other two; 138kV and 145kV can share some structures but require adjustment of the voltage sampling threshold; ② Key selection points — 138kV prioritizes matching interfaces of imported equipment, 145kV focuses on maturity, and 252kV needs to verify the breaking capacity of ≥63kA and the insulation coordination test report.

Q: What are the requirements for monitoring the gas decomposition products of the SF6 tank circuit breaker?
A:

During the normal operation and interruption processes of a circuit breaker, SF₆ gas can decompose, producing various decomposition products such as SF₄, S₂F₂, SOF₂, HF, and SO₂. These decomposition products are often corrosive, toxic, or irritating, and therefore require monitoring.If the concentration of these decomposition products exceeds certain limits, it may indicate abnormal discharges or other faults within the arc quenching chamber. Timely maintenance and handling are necessary to prevent further damage to the equipment and to safeguard personnel health.

Q: What are the leakage rate requirements for the arc quenching chamber of a tank-type circuit breaker?
A:

The leakage rate of SF₆ gas must be controlled at an extremely low level, typically not exceeding 1% per year. SF₆ gas is a potent greenhouse gas, with a greenhouse effect 23,900 times that of carbon dioxide. If a leak occurs, it can not only cause environmental pollution but also lead to a decrease in the gas pressure within the arc quenching chamber, affecting the performance and reliability of the circuit breaker.

To monitor the leakage of SF₆ gas, gas leakage detection devices are typically installed on tank-type circuit breakers. These devices help to promptly identify any leaks so that appropriate measures can be taken to address the issue.

Q: What are the structural characteristics of the tank circuit breaker?
A:

Integral Tank Structure:

  • Integral Tank Structure: The breaker's arc quenching chamber, insulating medium, and related components are sealed within a metal tank filled with an insulating gas (such as sulfur hexafluoride) or insulating oil. This forms a relatively independent and sealed space, effectively preventing external environmental factors from affecting the internal components. This design enhances the insulation performance and reliability of the equipment, making it suitable for various harsh outdoor environments.

Arc Quenching Chamber Layout:

  • Arc Quenching Chamber Layout: The arc quenching chamber is typically installed inside the tank. Its structure is designed to be compact, enabling efficient arc quenching within a limited space. Depending on different arc quenching principles and technologies, the specific construction of the arc quenching chamber may vary, but generally includes key components such as contacts, nozzles, and insulating materials. These components work together to ensure that the arc is quickly and effectively extinguished when the breaker interrupts the current.

Operating Mechanism:

  • Operating Mechanism: Common operating mechanisms include spring-operated mechanisms and hydraulic-operated mechanisms.

  • Spring-Operated Mechanism: This type of mechanism is simple in structure, highly reliable, and easy to maintain. It drives the opening and closing operations of the breaker through the energy storage and release of springs.

  • Hydraulic-Operated Mechanism: This mechanism offers advantages such as high output power and smooth operation, making it suitable for high-voltage and high-current class breakers.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.