12kV/24kV/36kV/40.5Kv Compact Substation

  • 12kV/24kV/36kV/40.5Kv Compact Substation

Key attributes

Brand ROCKWILL
Model NO. 12kV/24kV/36kV/40.5Kv Compact Substation
Rated voltage 40.5kV
Rated normal current 630A
Rated frequency 50/60Hz
Series YBM

Product descriptions from the supplier

Description

Descripton

The YBM series products represent a highly integrated power distribution solution, meticulously assembling medium-voltage (MV) switchgear, transformers, and low-voltage (LV) distribution equipment based on fixed connection schemes. Engineered for versatility, this series of substations is ideally suited for diverse applications, including neighborhood utility units, hotels, large-scale construction sites, and high-rise buildings. It operates efficiently within voltage ranges of 12kV, 24kV, 36kV, and 40.5kV, at a frequency of 50Hz, and can handle capacities of up to 2500kVA.

Adhering to stringent international standards, the YBW series complies with IEC60076 and IEC1330, as well as the ANSI/IEEE standards C57.12.00, C57.12.20, and C57.12.90. Additionally, it meets the requirements of BS171 and SABS 780, ensuring reliable performance and quality assurance across various regions and industries.

Structure Characteristics

  • Our box type transformer substations come in two distinct configurations: corridor - style and non - corridor - style. The frames are constructed from high - quality anti - corrosive steel through welding, while the bases are made of hot - galvanized steel.

  • Each box - type transformer substation consists of three compartments: the high - voltage (HV) cabinet, the low - voltage (LV) cabinet, and the transformer cabinet. The internal layout can be tailored to specific customer needs. The double - layer roof design features an air - filled cavity, which provides effective insulation against temperature increases.

  • These substations rely on natural air cooling as the standard option. However, forced air cooling and automatic anti - condensation equipment can be added as optional enhancements. To safeguard the transformer, various combinations of load switches and fuses are available.

  • They support multiple power supply modes, including terminal power supply, ring power supply, and dual power supply. The LV cabinets have a welded structure and are equipped with screen - type nameplates. Additionally, the cabinets are firmly fastened to the tank for stability.

Main Technical Specifications

Service Condition

  • Both indoor or outdoor

  • Air temperature: 

  • Maximum temperature: +40℃; Minimum temperature:-25℃

  • Humidity: Monthly average humidity 95%; Daily average humidity 90% .

  • Altitude above sea level: Maximum installation altitude: 2000m.

  • Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.

  • No frequent violent shake

Note: Beyond those services condition should enquiry to manufacturer technical dept during order

Note: The above parameter is only subject to our standard design, special requirement can be customized


Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.