• 12kV Indoor compressed load break switch
  • 12kV Indoor compressed load break switch
12kV Indoor compressed load break switch
discuss personally
Model
FKN12-12
Basic info
Brand ROCKWILL
Model NO. 12kV Indoor compressed load break switch
Rated voltage 12kV
Rated normal current 630A
Rated frequency 50/60Hz
Series FKN
Product Detail

Product Overview

The FKN12 - 12D pneumatic load break switch (hereinafter referred to as the load break switch) is an indoor high - voltage switching device for three - phase AC 12kV, 50/60Hz. Under normal circuit conditions, it can close, carry and open load current; it can close short - circuit current and has the ability to carry short - circuit current within a specified time. After the load break switch is equipped with a current - limiting fuse with an impactor, it becomes a load break switch - fuse combined electrical appliance (hereinafter referred to as the combined electrical appliance), which can be used for overload and short - circuit protection of loads (such as power transformers).

This product is suitable for installation in ring main unit switch cabinets, box - type substations and other types of switch cabinets. It is an ideal equipment for the construction, transformation and renewal of current distribution networks, transformation and distribution substations and switch stations.

 

Key Features

Current Handling Capability:Under normal operation, it can smoothly close, carry, and interrupt load current; in the event of a short - circuit fault, it is capable of closing short - circuit current and carrying short - circuit current within the specified time, ensuring short - term stability of the power grid during faults and gaining time for fault elimination.

Combined Protection Feature:When combined with a current - limiting fuse with an impactor, it forms a load break switch - fuse combination electrical appliance, providing overload and short - circuit protection for loads such as power transformers. This simplifies the system protection configuration and enhances the timeliness and effectiveness of protection.

Compact Structure:Based on the pneumatic arc - extinguishing principle, the overall structure is exquisitely designed with a small footprint, suitable for installation in indoor switchgear with limited space.

Flexible Installation:It has strong compatibility with various types of switchgear such as ring main unit switchgear and box - type substations. It can be conveniently installed in both new construction and renovation projects, reducing construction difficulty and costs.

Technical Parameters

Mechanical Characteristics

Operating Environmental Conditions

  •  Altitude: Not exceeding 1000m;

  •  Ambient Temperature: Maximum +40°C, Minimum -25°C;

  • Relative Humidity: Daily average not exceeding 95%, Monthly average not exceeding 90%;

  • Seismic Intensity: Below 8 degrees;

  • This switch should be installed in places free from fire, explosion hazards, severe pollution, chemical corrosion, and violent vibration.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!