22kV 24kV 25.8kV 27kV Self-powered single-phase Automatic Recloser / Reclosure Direct Supply

  • 22kV 24kV 25.8kV 27kV Self-powered single-phase Automatic Recloser / Reclosure Direct Supply
  • 22kV 24kV 25.8kV 27kV Self-powered single-phase Automatic Recloser / Reclosure Direct Supply

Key attributes

Brand ABB
Model NO. 22kV 24kV 25.8kV 27kV Self-powered single-phase Automatic Recloser / Reclosure Direct Supply
Rated voltage 27kV
Rated normal current 200A
Rated frequency 50/60Hz
Series Eagle

Product descriptions from the supplier

Description

Product Introduction

Product Range:Up to 27kV, 200A, 8kA

This is a single phase self-powered vacuum interrupting recloser. It can be mounted directly to the pole as a new installation or a replacement to oil filled single-phase reclosers. It can be installed separately on single phase laterals or in a group of three for a three-phase lateral circuit.
Eagle recloser drastically improves the reliability indices for utilities simply by eliminating the sustained interruptions experienced by the customers due to fuse-blowing schemes and momentary interruptions due to fuse-saving schemes. By reducing the number of truck rolls, the utility can save on operational costs and at the same time avoid revenue losses due to outages.
Eagle provides highest interrupting rating among its class with higher BIL (basic insulation level) and continuous current rating providing application from major three-phase feeder laterals to the end-of-line single phase laterals.

Technical parameters

The voltage classes of some of these Automatic Reclosers include 6kV, 6.3kV, 6.6kV, 6.9kV, 7.2kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV, 13.2kV, 13.8kV, 14.5kV, 14.4kV, 15kV, 15.5kV, 15.6kV, 17.5kV, 20kV, 21.9kV, 22kV, 24kV, 30kV, 33kV, 33.5kV, 34.5kV, 35kV, 36kV, 38kV, 38.5kV, 40.5kV, 44kV, 45kV, 46kV, 66kV and 69kV. Rated Short-Circuit Breaking Current includes 8kA, 12.5kA, 16kA, 20kA, 25kA, 31.5kA and customization is available.

The following technical parameters fully present the product's electrical parameter configurations, mechanical performance parameters, and dimensional details to facilitate precise system integration and application planning.

Technical specifications for hardware

Nominal operating voltage

15/27 kV

Rated max. Voltage

27 kV

Rated power frequency

60 HZ

Rated continuous current

200 A

Rated symmetrical interrupting current

8 kA RMS

Rated short-time withstand current

8 kA

Rated short-time withstand duration

1 sec

Rated peak-withstand current

20.8 kA

Rated lightning impulse withstand voltage (BIL)

125 kV

Rated power frequency dry/wet withstand (60 s)

60 kV

Creep distance H1 to H2 terminal

668 mm

Recloser unit weight

20 kg (44 lb)

Auxiliary power

12 V DC (for programming)

Operating temperature

-25 °C to +60 °C

Rated number of operations

10,000 operations

Ingress protection

IP65

Standards compliance

IEEE C37.60/IEC 62271-111

Technical specifications for electronics and software

Modes of operation

Autorecloser

Sectionalizer  

Breaker/switch

Rated operating duty

Min O 0.2 s CO 2 s CO 2 s CO lockout

Max O 5 s CO 5 s CO 20 s CO lockout

Minimum pickup fault current

10 A

Minimum current for WI-FI communication

5 A (1)

Minimum power-up time

25 ms

Protection functions

50/51P

Other functions

Second harmonic inrush restraint

Cold load pickup

Non-reclose/hot line tag

Switch on to fault

TCC curve accuracy

> 50 A: ±1%

> 20 A: ±2.5%

> 10 A: ±5%

< 10 A: ±1.6 A

Operating curves

ANSI/IEC, recloser, fuse, hydraulic and custom curves

Records

Events and fault records (1000)

Internal device events (100)

Disturbance records (250)

Load profile (60 days)

Security log (1000)

Communication

Wi-Fi with WPA2 128 Bit-Encryption

Auto Disable Feature

Hide SSID Feature

( 1) Tripping/reclosing capability is not dependent on availability of a specific minimum preload current.

Key features

Key features highlight the product&rsquo;s innovative design, high-performance capabilities, and operational advantages, ensuring optimal suitability for diverse industrial and power system requirements.

  • Can function as a recloser, breaker, or a sectionalizer

  • Main operating handle for mechanical opening, closing and resetting without relying on battery backup

  • Mounting design that allows manual swing down open for a visual disconnect

  • Conventional open/close indicator cup semaphore and a LED beacon for lockout indication

  • Adaptable non-reclose and hot line tag modes

  • Wide selection of fuse, recloser and user programmable protection curves

  • Platform / device independent web-based user interface

  • Full event, security, loading and fault recording capability with GPS time stamps

  • 128-bit encryption with WPA2 level security for Wi-Fi connection

  • Cold load pickup and 2nd harmonic inrush blocking for each curve

Key benefits

Key benefits underscore the product&rsquo;s reliability, efficiency, and cost-effectiveness, delivering tangible value for power distribution and industrial applications.

  • Can be applied on circuits up to 27kV, 200A &ndash; avoiding need to stock multiple part numbers

  • High fault current rating (8 kA) allows installation across the feeder

  • Self-powered design eliminating the need for an external power source

  • &ldquo;No arcing&rdquo; operations to keep personnel safety intact

  • Battery-free operations provide a truly maintenance-free life cycle

  • Ability to restore power after an extended outage without the need for batteries

  • One-to-one replacement for hydraulic reclosers by using identical mounting and protection curves

  • Hassle-free web-based interface and secure Wi-Fi communication

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 20000m² Total staff: Highest Annual Export(usD): 580000000
Workplace: 20000m²
Total staff:
Highest Annual Export(usD): 580000000
Services
Business Type: Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Electrical House (eHouse) Solutions
    Reduce site complexity, improve lead timeABB eHouses are prefabricated transportable substations, designed to house medium voltage and low voltage switchgear, critical power equipment and automation cabinets.An eHouse solution is a cost effective, risk reduced alternative to conventional concrete block and brick construction. Each eHouse module is custom engineered to meet application requirements with respect to equipment layout, site footprint limitations and logistics considerations.Installat
    04/16/2025
  • Improve speed to deployment Modular prefabricated and pre-engineered solutions
    Reduce site works and risk of schedule delays and cost overrunsOverview:With a complicated data center project that has short delivery timelines, prefabricated modular solutions and pre-engineered modular solutions may be the answer.Modular solutions are ideal for enterprise, colocation, edge and cloud data centers, where project replicability and expandability are critical, alongside fast deployment time.Reduce risk by leveraging prefabricated and integrated solutions:Fast track projects with p
    04/16/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.