24kV SF6 Insulated Switchgear/Ring Main Unit/RMU

  • 24kV SF6 Insulated Switchgear/Ring Main Unit/RMU

Key attributes

Brand ROCKWILL
Model NO. 24kV SF6 Insulated Switchgear/Ring Main Unit/RMU
Rated voltage 24kV
Rated frequency 50/60Hz
Series RMU

Product descriptions from the supplier

Description
Products Description

Our inflatable SF6 metal seal full insulation series ring network switch cabinet has passed the type test of the national occlusal electrical testing center. Widely used in 10KV/6K power distribution system, it is the preferred switch product for various users in urban and rural areas. switch cabinet is modular unit mode, which can be combined according to different purposes. By the combination of fixed units and expandable units, which substation meets the need of compact switchgear flexible use. Inflatable ring SF6 cabinet is divided into non-expandable standard configuration and expandable standard configuration. Due to the combination of full module and half module and its own scalability, it has extremely special flexibility. SF6 inflatable ring cabinet implemented GB standard. Under the condition of the interior (20 ℃) run the design life of more than 30 years.

Feature

  • High-efficiency insulation performance: Uses SF₆ gas as the insulating medium, featuring high insulation strength. It can operate stably at the 24kV voltage level, significantly reducing the risk of short circuits.
  • Compact design: Small in size, saving installation space, especially suitable for scenarios with limited space such as urban distribution networks and industrial parks.
  • High reliability: Boasts a tightly sealed structure, providing dustproof, moisture-proof, and anti-corrosion properties. It adapts to complex environments, reduces maintenance frequency, and improves power supply continuity.
  • Excellent safety performance: Equipped with a complete interlocking protection mechanism to prevent misoperation. Meanwhile, the SF₆ gas leakage detection function ensures safe operation.
  • Flexible adaptability: Supports multiple wiring methods, enabling quick connection with transformers, cables, and other equipment to meet the topological requirements of different distribution networks.
  • Environmental protection and economy: SF₆ gas can be recycled and reused. The equipment has a long service life and low long-term operating costs, balancing environmental protection and economic benefits.
 

Environmental Conditions

  • Suitable Altitude: ≤2000mSuitable
  • Temperature: -40℃ ~ +55℃Relative
  • Humidity: Daily mean ≤95%, monthly mean ≤90%
  • Gradation of Earthquake Damage: ≤ Level 8

 

Documentation Resource Library
Restricted
Electric Du Cambodge Technical Specification for 22 kV Ring Main Units
Other
English
Consulting
Consulting
Restricted
Bidding Document Supply, Test and Commissioning of MV Switching Stations (RMU) for Addis Ababa Distribution Network
Other
English
Consulting
Consulting
Restricted
EEHC Distribution materials specification for 24kv ring mian units
Other
English
Consulting
Consulting
Restricted
Metropolitan Electricity Authority Technical Specification NO.108 for 12/24kV Ring Main Units
Other
English
Consulting
Consulting
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Comparative Analysis of High-Voltage Load Switch Technologies
    A load switch is a type of switching device positioned between circuit breakers and disconnectors. It features a simple arc extinguishing device capable of interrupting rated load current and certain overload currents, but cannot interrupt short-circuit currents. Load switches can be classified into high-voltage and low-voltage types according to their operating voltage.Solid gas-producing high-voltage load switch: This type utilizes the energy from the breaking arc itself to cause gas-producing
    12/15/2025
  • Analysis of Faults and Solutions for 17.5kV Ring Main Units in Distribution Networks
    With the improvement of social productivity and people's quality of life, the demand for electricity is continuously increasing. To ensure the effectiveness of power grid system configuration, it is necessary to reasonably construct distribution networks based on actual conditions. However, during the operation of distribution network systems, 17.5kV ring main units play a very important role, so the impact caused by failures is extremely significant. At this point, it is essential to adopt reas
    12/11/2025
  • How to install a DTU on an N2 Insulation ring main unit?
    DTU (Distribution Terminal Unit), a substation terminal in distribution automation systems, is secondary equipment installed in switching stations, distribution rooms, N2 Insulation ring main units (RMUs), and box-type substations. It bridges primary equipment and the distribution automation master station. Older N2 Insulation RMUs without DTUs cannot communicate with the master station, failing to meet automation requirements. While replacing entire RMUs with new DTU-integrated models would sol
    12/11/2025
  • Design of a New 12kV Environmentally Friendly Gas-Insulated Ring Main Unit
    1. Specific Design1.1 Design ConceptState Grid Corporation of China actively promotes grid energy conservation and low-carbon development to achieve national carbon peak (2030) and neutrality (2060) goals. Environmentally friendly gas-insulated ring main units represent this trend. A new 12kV integrated environmentally friendly gas-insulated ring main unit was designed combining vacuum interrupter technology with three-position disconnectors and vacuum circuit breakers. The design utilized Solid
    12/11/2025
  • Integrated Intelligent Ring Main Units in 10kV Distribution Automation
    In the rational application of intelligent technologies, the integrated intelligent ring main unit in 10kV distribution automation construction is more conducive to improving the construction level of 10kV distribution automation and ensuring the stability of 10kV distribution automation construction.1 Research Background Integrated intelligent ring main unit.(1) The integrated intelligent ring main unit adopts more advanced technologies, including but not limited to network technology, communic
    12/10/2025
  • 35kV RMU Busbar Failure Due to Installation Errors Analysis
    This article introduces a case of 35kV ring main unit busbar insulation breakdown failure, analyzes the failure causes and proposes solutions [3], providing reference for the construction and operation of new energy power stations.1 Accident OverviewOn March 17, 2023, a photovoltaic desertification control project site reported a ground fault trip accident in the 35kV ring main unit [4]. The equipment manufacturer arranged a team of technical experts to rush to the site to investigate the cause
    12/10/2025

Related Solutions

  • Analysis of Common Problems in 10kV Gas-Insulated Ring Main Units (RMUs)
    Introduction:10kV gas-insulated RMUs are widely used due to their numerous advantages, such as being fully enclosed, possessing high insulation performance, requiring no maintenance, having a compact size, and offering flexible and convenient installation. At this stage, they have gradually become a critical node in urban distribution network ring-main power supply and play a significant role in the power distribution system. Problems within gas-insulated RMUs can severely impact the entire dist
    08/16/2025
  • Application of Intelligent Solid Insulated Ring Main Units (SIRMUs) in the Qinzhou Distribution Network
    1 IntroductionCoastal regions face environmental challenges including heavy rainfall, lightning, high temperatures, high humidity, and high salt spray corrosion. To ensure the safety of urban distribution grids in such environments, minimize power outages caused by equipment maintenance, and prevent accidents due to equipment end-of-life and other factors affecting grid security, we have researched the use of a new type of Solid Insulated Ring Main Unit (SIRMU). This SIRMU offers long lifespan,
    08/15/2025
  • SF₆ Ring Main Units (RMUs) and Urban Grid Renovation
    Overview​Older distribution networks are primarily radial in structure, with most incoming and outgoing lines being overhead lines. The switching equipment typically consists of air-insulated vacuum circuit breakers or minimal-oil circuit breakers. These networks suffer from frequent faults, high operating costs, and prolonged, widespread power outages in the event of a failure, significantly hindering economic development.With rapid economic growth and the implementation of urban grid renovatio
    08/13/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.