304 stainless steel photovoltaic isolation transformer

  • 304 stainless steel photovoltaic isolation transformer
  • 304 stainless steel photovoltaic isolation transformer

Key attributes

Brand ROCKWILL
Model NO. 304 stainless steel photovoltaic isolation transformer
Rated frequency 50/60Hz
Rated capacity 160kVA
Series SG

Product descriptions from the supplier

Description

Product Overview

Photovoltaic isolation transformers use low-loss materials and have the characteristics of high output conversion efficiency. The product has a high load capacity, anti-interference, fireproof, moisture-proof, safe and reliable, power-saving and convenient maintenance, etc., and plays the role of isolated power supply in photoelectric conversion, and can work normally for a long time in outdoor high-temperature environment. Solar energy has attracted more and more attention due to its advantages of no pollution, no noise and wide distribution. At present, most of the photovoltaic grid-connected power generation systems contain isolation transformers, and there is a leakage current problem in photovoltaic power generation systems without isolation transformers.

Product features:

  • Electrical isolation: The transformer is used to realize the electrical isolation between the photovoltaic power supply and the power grid.

  • Prevent the DC component of the current from being injected into the grid: Since the DC power does not cause a change in the magnetic flux, the DC component of the PV inverter system will not flow into the grid through the isolation transformer.

  • Anti-interference effect: the isolation transformer with a certain connection mode can eliminate the integer multiple harmonics of the 3rd and 3rd, and reduce the impact of higher harmonics and voltage fluctuations on the power grid.

  • The role of stable voltage: when the system fails, it can effectively suppress the resonant overvoltage and steady-state overvoltage of the photovoltaic inverter system.

Technical data:

304 stainless steel photovoltaic isolation transformer.png

304 stainless steel photovoltaic isolation transformer.png

 

  • Outdoor Large-Scale PV Power Plant Grid-Connection:Suitable for outdoor high-temperature/dusty environments such as deserts and plateaus. The 304 stainless steel enclosure resists corrosion, and the combination of high conversion efficiency and power isolation function prevents leakage current, ensuring grid-connection safety.

  • Industrial and Commercial Distributed PV Projects:Used for rooftop PV arrays of factories and commercial buildings. The DC component injection prevention function protects power grid quality, and the anti-interference feature eliminates 3rd and multiple harmonics, reducing interference to production/electrical equipment.

  •  Coastal/High-Salt-Fog Area PV Systems:Targeting coastal and island projects. 304 stainless steel resists salt-fog corrosion; combined with fireproof and moisture-proof properties, it adapts to humid and rainy climates, ensuring stable power generation.

  • Special PV Scenarios with High Reliability Requirements:Applicable to PV + energy storage microgrids and backup power for hospitals/data centers. The voltage stabilization function suppresses fault overvoltage, and electrical isolation prevents grid interference, ensuring the safety of critical loads.


Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.