• 35kV Low Loss Prefabricated Compact Substation for Grid
35kV Low Loss Prefabricated Compact Substation for Grid
discuss personally
Model
YBW-35
Basic info
Brand POWERTECH
Model NO. 35kV Low Loss Prefabricated Compact Substation for Grid
Rated voltage 35kV
Series YBW-35/0.4-2000
Product Detail

Description

An AC metal-enclosed shift switch cabinet is a three-phase, 50Hz indoor metal-enclosed switching device designed for power plants and substation systems. It operates at a rated voltage of 35kV, with a maximum current capacity of 2000A and a voltage limit not exceeding 40.5kV. Suitable for single-bus or single-bus segmented configurations, it serves as a reliable distribution solution.

This switchgear complies with standards such as DL/T 404-91, IEC 298, and GB 3906, incorporating essential safety features to prevent operational errors. These include protections against incorrect circuit breaker operation, live insertion or withdrawal of trolleys, grounding line faults, live grounding, and accidental energization of isolated sections (commonly referred to as the "five protections").

Compact substations are ideal for diverse applications, including residential communities, urban public distribution networks, busy downtown areas, and temporary construction power supply. Their versatility allows selection based on specific load requirements and environmental conditions. Since their introduction, compact substations have seen rapid adoption, with widespread use in developed countries—where they account for a significant share of distribution systems. In China, modernization and urban grid upgrades are driving their increasing deployment.

These substations are commonly employed in high-rise buildings, luxury residences, parks, residential complexes, small to medium industrial plants, mining operations, oil fields, and temporary construction sites, providing efficient power distribution within electrical networks.

 Features

  • Complete Power Distribution System – Integrates transformation, distribution, transmission, measurement, compensation, control, protection and communication functions in one unit.
  • Standardized Components – Consists of high-voltage switchgear, distribution transformer, low-voltage distribution panel and protective enclosure.
  • Outdoor Application Design – Features anti-corrosion, waterproof and dustproof construction suitable for long-term outdoor operation.
  • Compact Structure – Three-section integrated design (high-voltage, transformer, low-voltage) with small footprint.
  • Installation Advantages – Offers flexible siting, reduced civil works, shorter construction period and lower overall cost compared to conventional substations.
  • Reliable Operation – High operational stability with comprehensive protection functions.
  • Aesthetic Appearance – Modern enclosed design with better visual appeal than traditional solutions.
  • Wide Application Range – Ideal for urban grid upgrades, residential communities, industrial parks, commercial centers, transportation facilities and temporary power supply needs.
  • Technical Compliance – Meets relevant industry standards for performance and safety requirements.
  • Maintenance Friendly – Modular design simplifies inspection and servicing procedures.

Parameter

Know your supplier
POWERTECH
We are an electrical company that manufactures and sells high and low voltage electrical products.
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$120000000
Professional Experience
7 years
Workplace
580000m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!