• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Class-A 5.12KWh Low Voltage Energy Storage Battery for Energy Storage System

  • Class-A 5.12KWh Low Voltage Energy Storage Battery for Energy Storage System

Key attributes

Brand Wone Store
Model NO. Class-A 5.12KWh Low Voltage Energy Storage Battery for Energy Storage System
Rated voltage 51.2 V
Rated capacity 5.12kWh
Series JKS

Product descriptions from the supplier

Description

 

Features

  • > 6,000 cycles backed by Jinkosolar 10-years authoritive warranty.

  • Multiple battery protections including communication, MOS, 2nd fault mandatory protection to enable overall full protection.

  • Compatible to charge/discharge at 0.5C and 1C, but at 0.5C is recommended.

  • Protection rating at IP65, cell-level independent fire-proof design, fire-resistant material can be exposed to 1200 degrees Celsius flame.

  • Compatible to diseal engine power plants and UPS application with on/off grid shifting times as low as 10 seconds.

  • Plug and play connecion saves 40% installation time.(no professional electrician needed for home use)

  • Over 35 technical and services centers globally, world-widely distributed network and parters.

  • All-in-one PV+ solution provides packed warranty, one-stop service and support.

     

In The Energy System Architecture

image.png

Technology Parameters

Physical

image.png

Electrical

image.png

Operation

image.png

Certification

image.png

企业微信截图_17212876202884.png

  •  Power button

  •  LED indicator 

  •  Hidden handle

  • Hidden cable connection box

Working principle:

  • Charging process:When the battery is charging, lithium ions are deintercalated from the cathode material (LiFePO4), move to the anode (usually graphite) through the electrolyte, and combine with the anode material to form a lithium intercalation compound.Electrons flow from the cathode to the anode through the external circuit to form a current.

  • Discharging process:When the battery is discharging, lithium ions are deintercalated from the anode, move back to the cathode through the electrolyte, and at the same time, electrons flow from the anode to the cathode through the external circuit to provide electrical energy to the load.

Application scenarios

  1. UPS backup power supply for small commercial premises (such as convenience stores, small offices)Adaptation advantages: The product supports UPS system access, and the off-grid switching time is no more than 10 seconds, which can quickly respond to sudden power outages in the power grid; The IP65 dustproof and waterproof design can be installed in the corner of the store or outdoors without additional protection; A single battery pack can support cash registers, refrigerators, and emergency lighting to work continuously for 4-6 hours, avoiding problems such as product deterioration and loss of cash register data caused by power outages, and is especially suitable for 24-hour convenience stores, community supermarkets and other scenarios.

  2. Home emergency energy storage (to cope with extreme weather or power grid fluctuations)Adaptation advantages: -30℃~55℃ wide temperature range, plug-and-play design without professional electricians, ordinary families can install it on the balcony or garage by themselves; The 5.12kWh capacity can meet the continuous power supply of refrigerators (0.8kWh per day), routers (0.1kWh per day), and lighting (0.2kWh per day) for 3-5 days, solving the problem of long-term power outages caused by disasters such as typhoons and heavy rains, and ensuring basic household electricity needs.

  3. Energy storage supporting diesel generators in remote areas (such as rural workshops, outdoor operations)Adaptation advantages: It can be linked with diesel generators to make up for the shortcoming of generator startup delay —— when the power grid is cut off, the battery supplies power first, and then switches after the generator starts to avoid power supply interruption; The low-voltage characteristic is adapted to the output voltage of small diesel generators, without additional voltage converters; 6000 long cycle life, which can be used for frequent charging and discharging, suitable for scenarios such as rural workshops and outdoor infrastructure construction sites where "the power grid is unstable and dependent on generators", reducing the frequency of generator startup and shutdown and fuel consumption.

  4. Supporting small household wind-solar energy storage systems (such as household photovoltaics / small wind power)Adaptation advantages: It supports linkage with household photovoltaic panels and small wind turbines, can store excess electricity generated by wind and solar energy during the day, and supply it to household lighting, washing machines and other equipment at night, reducing dependence on the power grid; IP65 protection can be installed on the roof or courtyard together with wind and solar equipment, with weather resistance matching the outdoor environment, and the plug-and-play design simplifies the installation process of the whole system, suitable for family users pursuing "clean energy saving + electricity bill saving".

 

 

 

 

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings/Instrument Transformer/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Dedicated Vacuum Contactor Solution for Port Shore Power Systems
    I. Background and Challenges​Shore power systems have become core technical equipment for ports to reduce carbon emissions and noise pollution. However, these systems face two major challenges in the harsh operational environment of ports:​Severe Environmental Corrosion: High humidity and salt spray in port areas cause serious corrosion to metal components and enclosures of electrical equipment, significantly impacting electrical lifespan and operational reliability.​High Switching Requirements:
    09/13/2025
  • ABB Vacuum Contactor KC2 Power Supply System Technical Transformation Plan
    Issue Overview​The 10kV air compressor starting system of a company utilizes the ABB vacuum contactor KC2 as the control component for the operating circuit. The dedicated wide-voltage power supply module paired with this contactor presents the following issues:​Frequent failures: The power supply module fails to properly transition the voltage from 300V to 12V, resulting in fuse blowouts.​Poor heat dissipation: Enclosed installation of the module leads to insufficient heat dissipation, acceler
    09/13/2025
  • Solution for Medium-Voltage Motor Control and Protection Using Vacuum Contactor-Fuse (VCF) in a Coal Conveying System
    1.Project BackgroundA coal conveying system comprises 15 belt conveyors driven by medium-voltage motors. The system operates under complex conditions, with motors often subjected to heavy loads and frequent starts. To address these challenges and achieve effective control and reliable protection during motor startup, the project comprehensively adopts Vacuum Contactor-Fuse (VCF) combination devices for the 6kV medium-voltage motor power distribution. This solution details the technical features,
    09/13/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.