Completely insulated SF6 Ring Main Unit 12kV 24kV 40.5kV

  • Completely insulated SF6 Ring Main Unit 12kV 24kV 40.5kV

Key attributes

Brand Rw Energy
Series RMR
Rated voltage 12kV / 24kV / 40.5kV
Rated current 630A 1250A
Rated Frequency 50Hz / 60Hz

Product descriptions from the supplier

Description
Description
The RMR series is a fully SF6 insulated ring main unit designed as a high-safety combined switchgear, complying with GB and IEC international standards. Equipped with high-performance circuit breakers and load break switches as core components, it features advanced technology, reliable performance and safe operation.
This RMU integrates multiple functional units and connecting busbars into a sealed SF6 gas tank with no live parts exposed. It offers full insulation, maintenance-free operation, compact structure and convenient operation. The cabinet is made of 3.0mm thick stainless steel, providing excellent protection against moisture, corrosion and salt spray. It has successfully passed a full range of tests including breaking test, dynamic and thermal stability test, sealing test and mechanical test, ensuring maximum safety for operators and equipment. Suitable for both indoor and outdoor installation, it features strong resistance to harsh environments.
The RMR series SF6 ring main unit is widely applied in industrial and civil ring network distribution systems and power supply terminals.
Key Features
  • Fully sealed SF6 insulated structure with no exposed live parts, safe and maintenance-free
  • Compact size, reasonable layout and easy for installation and operation
  • 3.0mm stainless steel cabinet with good performance against moisture, corrosion and salt spray
  • High reliability core components: circuit breaker and load break switch with stable performance
  • Passed comprehensive type tests to ensure personal and equipment safety
  • Strong environmental adaptability, suitable for indoor and outdoor use
  • Complies with IEC and GB standards, with high safety and interchangeability
RMR-12/24 Type ring main unit

SF6-insulated ring main unit and SF6-insulated compact switchgear are used in medium voltage distribution networks. They offer a sealed stainless steel tank which contains all the live components and switching functions. The transformer is protected either by a switch fuse combination or a vacuum circuit breaker.SF6-insulated ring main unit can be supplied as a 2, 3 or 4-way unit in standard configurations with additional equipment according to customer specification.SF6-insulated compact switchgear has a unique flexibility due to its extendibility and the possible combination of fully modular and semi-modular configurations, with a maximum of 5 modules in one SF6-tank.The units are delivered from the factory ready for installation. Routine tests are carried out on all units/ modules before dispatch. No special tools are required for installing the equipment.

RMR-12/24 /40.5 Type ring main unit

RMR use SF6 – gas (Sulphur hexafluoride) as insulation and quenching medium.The SF6 is contained in a welded stainless steel tank, which is sealed for life.The pressure system is defined as a sealed for life system with an operating life time exceeding 30 years. The leakage rate is less than 0.1% per year. In order to ensure a reliable and tight welding, all welding work is carried out by computer controlled robots.Electrical and mechanical bushings penetrating the tank are clamped and sealed to the tank by high quality O-rings.The mechanical bushing has in addition a rotating shaft which connects the shaft of the switch to the corresponding shaft of the mechanism. The rotating shaft is sealed by a double set of gas seals.All SF6-tanks have to pass a leakage test before gas fill-ing. Leakage test and gas filling are done inside a vacuum chamber. The first step in the leakage test is to evacuate all air inside both SF6-tank and vacuum chamber simultaneously. Then the SF6-tank is filled with Helium. Due to the characteristics of Helium this test will detect all possible leakages. If the SF6-tank passes this test, the Helium will be evacuated and replaced by SF6.The SF6-tank has a degree of protection of IP65 and can be immersed into water and still maintainable functions in a satisfactory way.

Standards Compliance

IEC62271-200, IEC62271-100, GB3804-2004, GB3906-1991, GB16926-1997, GB/T11022-1999

Operating Conditions

  • Ambient air temperature: ±40℃, daily average ≤25℃
  • Altitude: up to 4000m
  • Wind speed: ≤35m/s
  • Seismic intensity: ≤8 degree
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 30000m² Total staff: Highest Annual Export(usD): 100000000
Workplace: 30000m²
Total staff:
Highest Annual Export(usD): 100000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Robot
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026

Related Solutions

  • Design Solution of 24kV Dry Air Insulated Ring Main Unit
    The combination of Solid Insulation Assist + Dry Air Insulation represents the development direction for 24kV RMUs. By balancing insulation requirements with compactness and employing solid auxiliary insulation, insulation tests can be passed without significantly increasing phase-to-phase and phase-to-ground dimensions. Encapsulating the pole column solidifies the insulation for the vacuum interrupter and its connecting conductors.Maintaining the 24kV outgoing busbar phase spacing at 110mm, the
    08/16/2025
  • Optimization Design Scheme for the 12kV Air-Insulated Ring Main Unit Isolating Gap to Reduce Breakdown Discharge Probability
    With the rapid development of the power industry, the ecological concept of low-carbon, energy-saving, and environmental protection has been deeply integrated into the design and manufacturing of power supply and distribution electrical products. The Ring Main Unit (RMU) is a key electrical device in distribution networks. Safety, environmental protection, operational reliability, energy efficiency, and economy are inevitable trends in its development. Traditional RMUs are primarily represented
    08/16/2025
  • Analysis of Common Problems in 10kV Gas-Insulated Ring Main Units (RMUs)
    Introduction:10kV gas-insulated RMUs are widely used due to their numerous advantages, such as being fully enclosed, possessing high insulation performance, requiring no maintenance, having a compact size, and offering flexible and convenient installation. At this stage, they have gradually become a critical node in urban distribution network ring-main power supply and play a significant role in the power distribution system. Problems within gas-insulated RMUs can severely impact the entire dist
    08/16/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.