DC miniature circuit breaker

  • DC miniature circuit breaker

Key attributes

Brand Wone Store
Model NO. DC miniature circuit breaker
Rated frequency 50/60Hz
Series DCB

Product descriptions from the supplier

Description

Description

Product introduction:  DC small circuit breaker is suitable for lines with rated current of 125A and below DC current, rated DC voltage of 250V and 500V. GYM9-125DC series DC small circuit breaker adopts the overload and short circuit protection design of DC power distribution system facilities and electrical, which can be widely used in electric power.

Product Features

  • The design structure consists of the shell, operating mechanism, thermal tripper, electromagnetic release contact system, arc extinguishing system, etc

  • It has the function of overload and short circuit protection.

  • Powerful permanent magnet arc fire extinguishing system, so that the short circuit capacity of the product reaches 6KA.

  • 35mm standard rail installation.

  • The window design can make the product status clear at a glance and avoid misoperation.

  • Widened handle design to make the product easier to operate.

  • Anti-crack buckle design enhances product durability and prolongs product life.

  • The flame-retardant shell design greatly improves product safety.

DC small circuit breaker selection parameters

Test DC experimental current Start state Tripping or no tripping
time limit
Expected
results
remark
a 1.05In Cold t≥1h(In≤63A)
t≥2h(In>63A)
There is no tripping
device

b 1.3In After testing immediately t<2h(In>63A)
t<1h(In&le;63A)
Tripping
device
The current steadily rises to
the specified value within 5S
C 8In Cold t&ge;0.2s There is no tripping
device
Turn off the auxiliary switch
and turn on the power
12In t<0.2s Tripping
device

Working Environment:

  • The ambient air temperature should not exceed +40&deg;C, low should not exceed -5&deg;C, and the average value should not exceed +35&deg;C.

  • The altitude of the installation site should not exceed 2000 meters.

  • When the ambient temperature is high, the relative humidity of the atmosphere does not exceed 50%, and the temperature is +40&deg;C, which can have a higher relative at lower temperatures

  • Humidity:The average relative humidity in the wet month is 90%, and the average relative humidity in the month is 90%. Taking into account the average low temperature

  • +25&deg;C condensation on the surface of the product due to temperature changes.

  • The pollution level is level 2.

  • The installation category is level 2 and level 3.

  • Use TH35-7.5 steel mounting rail for installation.

  • The inclination of the mounting surface and vertical surface should not exceed 5&deg;.

  • Compress the wire with screws.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings/Instrument Transformer/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Rockwill Passes Single-Phase Ground Fault Test for Smart Feeder Terminal
    Rockwill Electric Co., Ltd. has successfully passed the real-scenario single-phase-to-ground fault test conducted by the Wenzhou of China Electric Power Research Institute for its DA-F200-302 hood-type feeder terminal and integrated primary-secondary pole-mounted circuit breakers—ZW20-12/T630-20 and ZW68-12/T630-20—receiving an official qualified test report. This achievement marks Rockwill Electric as a leader in single-phase ground fault detection technology within distribution networks.The DA
    12/25/2025
  • Case Studies of Installation and Manufacturing Defects in 110kV HV Circuit Breaker Porcelain Insulators
    1. SF6 gas leakage occurred in the ABB LTB 72 D1 72.5 kV circuit breaker.Inspection revealed gas leakage at the fixed contact and cover plate area. This was caused by improper or careless assembly, where the dual O-rings slipped and were misplaced, resulting in gas leakage over time.2. Manufacturing Defects on the Outer Surface of 110kV Circuit Breaker Porcelain InsulatorsAlthough high-voltage circuit breakers typically have their porcelain insulators protected with covering materials during tra
    12/16/2025
  • Overview of Defect Diagnosis Methods for High-Voltage AC Circuit Breakers
    1. What are the characteristic parameters of the coil current waveform in high-voltage circuit breaker operating mechanisms? How to extract these characteristic parameters from the original trip coil current signal?Answer: The characteristic parameters of the coil current waveform in high-voltage circuit breaker operating mechanisms may include the following: Steady-state peak current: The maximum steady-state current value in the electromagnet coil waveform, representing the position where the
    12/16/2025
  • A Brief Discussion on the Issues of Converting Reclosers into Outdoor Vacuum Circuit Breakers for Use
    The rural power grid transformation plays an important role in reducing rural electricity tariffs and accelerating rural economic development. Recently, the author participated in the design of several small-scale rural power grid transformation projects or conventional substations. In rural power grid substations, conventional 10kV systems mostly adopt 10kV outdoor auto circuit vacuum reclosers.To save investment, we adopted a scheme in the transformation that removes the control unit of the 10
    12/12/2025
  • A Brief Analysis of Automatic Circuit Recloser in Distribution Feeder Automation
    An Automatic Circuit Recloser is a high-voltage switching device with built-in control (it inherently possesses fault current detection, operation sequence control, and execution functions without requiring additional relay protection or operating devices) and protective capabilities. It can automatically detect the current and voltage in its circuit, automatically interrupt fault currents according to inverse-time protection characteristics during faults, and perform multiple reclosures accordi
    12/12/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.