Din-Rail DC Watt Hour Meter

  • Din-Rail DC Watt Hour Meter
  • Din-Rail DC Watt Hour Meter

Key attributes

Brand Wone
Model NO. Din-Rail DC Watt Hour Meter
Rated voltage DC1kv
Rated normal current 2000A
Rated frequency 50(Hz)
Methods of Communication RS485
Series DEM2D002

Product descriptions from the supplier

Description

Description

Din Rail mounted,adopt flame retardant PC material,strong impact and weather resistance, and is suitable for various installation environments. The DC meter has tariff function, built-in clock chip. Clock error accuracy0.5s/day which guarantees the reliability of the tariff function.

Feaures

  • RS485 communication: used for parameter setting, data reading; DTL645 protocol/Modbus Protocal.

  • DC metering: using shunt sampling, high measurement accuracy; can measure DCpower, current,voltage.

  • Alarm function: Over-current alarm: When the current exceeds the CT1 value set by themeter, analarm event occurs, and the alarm light on the electrical surface panel lights up (yellowlight), At the same time, the value of the corresponding alarm status register will change, and theuser canread this register through communication to determine whether an over-current alarmhas occurred.

  • Display: LCD with backlight ,Support Various parameters display,energy data and Instantaneousparameters.

  • One channel relay out put (Used for over current cut off ).

  • Firmware upgrade: RS485 local upgrade.

Specifications


Main
Range DEM
Model NO. DEM2D002D114071-HPLCD114071-HPLCvHPLCD114071-HPLC D114071-HPLCD114071-HPLC 
Product or Componet Type Energy meters
Country of origin China


Complementary
Phase Single Phase
Device Application Din-Rail
Accuracy class Class1.0  active energyIEC 62053-41
Accuracy current 0.5%
Voltage Accuracy 0.5%
Active Power Accuracy 1.0%
Rated voltage DC 5V~1000V
Auxiliary power supply 85~300V AC or 85-300V DC
Network Frequency 50Hz
Current Shunt connection method, the primary side

 current supports up to 2000A

Connection signal :75mV

Pulse constant 1000imp/kWh,

1.2 times the maximum voltage and current,

the pulse width is 1.2ms, corresponding to the current setting

AC withstand voltage 4400V/min
Impulse withstand voltage 6.4kV - 1.2/50µS waveform
Power consumption ≤8VA  ≤0.4W
Technology Type Electronic
Display Type LCD6+2
Communication port protocol DTL645
Communication port support RS485/Modbus
Standards IEC 62053-41
Environment
Ambient air temperature for operation -25~70℃
Ambient Air Temperature for Storage -25-70℃
Relative humidity ≤95%


ConnectlonDiagram

image.png













Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 65666m²m² Total staff: 300+ Highest Annual Export(usD): 50000000
Workplace: 65666m²m²
Total staff: 300+
Highest Annual Export(usD): 50000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.