• Dry isolating transformer
Dry isolating transformer
discuss personally
Model
IS11-20/380
Basic info
Brand Vziman
Model NO. Dry isolating transformer
Rated capacity 20KVA
Voltage grade 380V
Series Isolating Transformer
Product Detail

Product overview:

  • Dry isolating transformer is produced by Wone  with high quality materials and advanced technology. It has the advantages of moistureproof and convenient maintenance. It is mainly used in various power supply places with AC 50/60Hz and voltage not exceeding 660V.

  • Actual measurement is better than GB and IEC standards, CB CCC KEMA certification.

  • High reliability of operation verification in more than 50 countries and regions around the world.

  • Mainly used in various high and low voltage complete sets of electrical, precision machine tools, UPS, electroplating, lighting, heating, communication, chemical industry equipment control power, power supply.

  • Products are mainly exported to central Asia, Southeast Asia, the Middle East, Africa, South America and other markets and regions.

Product advantages:
Leading technology

  •  Copper foil winding technology, high quality A class insulation material insulation.

  •  Small magnetic leakage, high mechanical strength, strong short circuit resistance.

  •  Iron core 45° full oblique joint step laminated structure.

The iron core:

  • The core material is high quality cold rolled grain oriented silicon steel sheet with mineral oxide insulation (from  Baowu Steel Group, China).

  • Minimize loss level, no-load current and noise by controlling the cutting and stacking process of silicon steel sheet.

  • The iron core is specially reinforced to ensure the transformer structure is firm during normal operation and transportation.

winding:

  • Wrapped with high quality copper foil (customizable aluminum foil), excellent insulation resistancem.

  • High quality material.

  • Baowu Steel Group production of silicon steel sheet.

  • High quality anaerobic copper from China.

Ordering instructions:

  • Main transformer parameters.

  • Transformer operating environment.

  • Other customization requirements.

  • The minimum order quantity is 1 sets, worldwide delivery within 7 days.

  • Normal delivery period of 30 days, worldwide fast delivery.

What is galvanic isolation?

Transformer Isolation:

  • Principle: Electrical isolation is achieved by utilizing the magnetic coupling between the primary winding and the secondary winding of the transformer. There is no direct electrical connection between the primary winding and the secondary winding of the transformer, but energy can be transferred through the magnetic field.

  • Application: It is widely used in power adapters, medical devices, laboratory instruments, etc.

 Optocoupler Isolation:

  • Principle: Electrical isolation is realized by using an optocoupler (photoelectric coupler) to convert an electrical signal into an optical signal and then converting the optical signal back into an electrical signal. The optocoupler contains a light-emitting diode (LED) and a photosensitive element (such as a phototransistor) inside.、

  • Application: It is widely used in digital circuits, control systems, communication equipment, etc.

 Relay Isolation:

  • Principle: Electrical isolation is achieved by using the contact switches of the relay. There is no direct electrical connection between the coil circuit and the contact circuit of the relay, but signals can be transmitted through the switching action of the contacts.

  • Application: It is widely used in control systems, switching circuits, etc.

 Isolation Amplifier:

  • Principle: The input signal is isolated from the output signal by using an isolation amplifier while maintaining the amplification and transmission of the signal. The isolation amplifier usually contains isolation elements such as transformers or optocouplers inside.

  • Application: It is widely used in industrial measurement, sensor signal processing, etc.


Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!