GRV8-1UVR Single Phase Undervoltage Relay

  • GRV8-1UVR Single Phase Undervoltage Relay

Key attributes

Brand Switchgear parts
Model NO. GRV8-1UVR Single Phase Undervoltage Relay
Rated frequency 45Hz-65Hz
Series GRV8

Product descriptions from the supplier

Description

Product Highlight:

Reliable Protection: Shields motors, air conditioning systems, and other inductive loads from harmful under voltage conditions.

True RMS Measurement: Delivers precise voltage monitoring, even in environments with harmonics or distorted waveforms.

Wide Compatibility: Functions across a 45Hz to 65Hz frequency range, adaptable to diverse power systems.

High Precision: Offers voltage measurement accuracy of less than 1% for consistent performance.

User-Friendly Design: Features an LED status indicator and a compact 1-MODULE format for easy DIN rail mounting.

The GEYA GRV8-1UVR is a single-phase undervoltage relay specifically designed for industrial and commercial applications. It is intended to protect inductive loads, such as air conditioning systems and motors, from damage caused by sudden low voltage fluctuations. Utilizing advanced True RMS measurement technology, this device continuously monitors the supply voltage in real time and promptly disconnects the load when the voltage falls below a preset threshold, effectively preventing equipment damage and production interruptions.

Function: Under voltage

Rated supply voltage(Un):220V/230V/240V

Rated supply frequency:45Hz-65Hz

Under voltage threshold:Fixed 75% of Un

Applications:

Product is used for highly fluctuating inductive load such as Air.

Conditioning system inIndustrial and commercial establishments.

lt protects the system equipment and load from sudden under voltage fuctuations.

Item GRV8-1UVR Single Phase Undervoltage Relay
Function Under voltage
Monitoring terminials L-N
Supply terminals L-N
Rated supply voltage(Un) 220V/230V/240V
Rated supply frequency 45Hz-65Hz
Under voltage threshold R:fixed 75% of Un
Trip delay time(Tu) 0.1s
Hysteresis 5V
Measurement error ≤1%
Power on delay time(Td) Adjustable: 5min-15min
Recovery delay time(Tr) Adjustable: 5min-15min
Konb setting accuracy 10% of scale value
Supply indication green LED
Output indication red LED
Output 1×SPDT
Current rating 10A/AC1
Switching voltage 250VAC/24VDC
Mechanical life 1*107
Electrical life(AC1) 1*105
Operating temperature -20℃ to +55℃(-4℉ to 131℉)
Storage temperature -35℃ to +75℃(-22℉ to 158℉)
Mounting/DIN rail Din rail EN/IEC 60715
Protection degree IP40 for front panel/IP20 terminals
Operating position any
Overvoltage category III
Pollution degree 2
Max.Cable size(mm²) solid wire max.1×2.5or 2×1.5/with sleeve max.1×2.5(AWG 12)
Tightening torque 0.8Nm
Dimensions 90×18×64mm
Weight 63g,65g
Standards EN 60255-1,IEC60947-5-1
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.