• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


GSR-3 Three Phase Solid State Relay

  • GSR-3 Three Phase Solid State Relay

Key attributes

Brand Switchgear parts
Model NO. GSR-3 Three Phase Solid State Relay
Output current 10A
Series GSR

Product descriptions from the supplier

Description

The GSR1-3 AA three-phase solid state relay (SSR) is a high-performance contactless switching device developed based on modern microelectronics and power electronics technology. It is designed specifically for intelligent control of three-phase AC loads, using weak control signals (such as TTL, DTL, HTL logic levels) to safely drive high current loads and achieve electrical isolation between input and output circuits.

Applications:

AC DC switch & Temp control

Automate Control

CNC machinery

Packaging machinery

Textile machinery

Glass machinery

Plastic machinery

Wide input voltage range and small control current, less than or equal to 20mA;

No mechanical action parts, long service life, and high reliability;

Fast switching speed, zero voltage on, zero current off, low RF interference;

Built in resistance-capacitance absorption to protect the impact of the product on the starting instant current;

Photoelectric isolation between input and output circuits, insulation and withstand voltage of 2500V;

The product is small in size and filled with epoxy resin, which is shockproof, moisture-proof and corrosion-proof

input parameter                
Control voltage range 70-280VDC
Ensure shutdown voltage 50VAC
Ensure that the voltage is turned on 90VAC
General characteristics                
Installation mode Bolt fixing
Insulation and withstand voltage between input and output 2500Vrms
Insulation and withstand voltage between input and output and housing 4000Vrms
Leakage current under off state ≤8mArms ≤2mArms
Maximum control current 10mA
Minimum control current 5mA
On-off reaction delay ≤10ms
Output parameters                
Output voltage range 24-480VAC
Peak voltage 800VAC 1200VAC
Relevant certification CE
Saturation pressure drop in on state ≤1.5V
Specification / maximum load current 10A 25A 40A 60A 80A 100A 120A 200A
ambient temperature -20°~75°C
insulation resistance 1000MΩ/500VDC
size 105L×74W×33H
weight 500g

 

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.