• High Voltage Current-Limiting Fuse(For motor protection)
  • High Voltage Current-Limiting Fuse(For motor protection)
High Voltage Current-Limiting Fuse(For motor protection)
discuss personally
Model
XRNM-12/100
XRNM-12/200
XRNM-7.2/200
XRNM-7.2/100
XRNM-3.6/200
XRNM-3.6/100
Basic info
Brand Wone
Model NO. High Voltage Current-Limiting Fuse(For motor protection)
Rated voltage 12kV
Rated normal current 100A
Breaking capacity 63kA
Series Current-Limiting Fuse
Product Detail

Characteristic brief :

  • Rated voltage from 3.6KV to 12KV.

  • Wide range of rated current from 31,5A to 400A.

  • BS type and DIN type are all available.

  • Powerful pyrotechnic or spnng striker.

  • H.R.C.

  • Current-limiting.

  • Low power dissipation, low temperature rise.

  • Operation extremely quickly, high reliability.

  • With motor circuit in senes.

  • Isolating & protecting motor.

  • Conforming to stanaards: GB15166.2 DIN43625 BS2692-1 IEC60282-1.

Model illustration:

企业微信截图_17337950699738.png

Technical Parameters:

企业微信截图_17337951237327.png

 Fuse base table:

企业微信截图_17337953559567.png


 External&installation dimensions(Unit:tmm)

企业微信截图_17337954261819.png

BS Type XRNM1 single fuse link

企业微信截图_17337954352541.png

BS Type XRNM1 double fuse link

企业微信截图_17338112416149.png

BS Type XRNM1 three fuse link

企业微信截图_17338112496441.png

DIN Type XRNM2

How does a high-voltage current-limiting fuse (for motor protection) work?

Normal State:

  • During normal operation of the motor, the high-voltage current-limiting fuse has very low resistance, allowing the normal operating current to pass through without significantly affecting the motor circuit. It behaves like a well-conducting conductor.

Fault Protection:

  • When an overload or short-circuit fault occurs in the motor, causing the current to exceed the rated current of the fuse, the fusible element rapidly heats up due to the thermal effect of the current. Given the large magnitude of the fault current, the fusible element quickly reaches its melting point and melts, generating an arc.

  • At this point, the arc-quenching system, which includes materials such as quartz sand, absorbs the heat from the arc, causing it to extinguish rapidly. During this process, the fuse limits the peak value of the fault current, preventing the motor from experiencing excessive current surges.


Know your supplier
Wone
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!