• High-voltage direct current converter transformer(HVDC)
High-voltage direct current converter transformer(HVDC)
discuss personally
Model
ZZDFPZ-415000/500-800
Basic info
Brand ROCKWILL
Model NO. High-voltage direct current converter transformer(HVDC)
Rated frequency 50/60Hz
Series ZZDFPZ
Product Detail

Description

The high-voltage direct current (HVDC) converter transformer is a core device in HVDC transmission systems. Its main function is to connect the AC power grid with the converter valve, enabling energy conversion and transmission between AC and DC. It can convert high-voltage electrical energy on the AC side to a voltage level suitable for the operation of the converter valve, providing stable support for DC transmission. Meanwhile, through electrical isolation, it reduces mutual interference between the AC grid and the DC system, ensuring the safe operation of the entire transmission system. Its performance directly affects the efficiency, stability, and reliability of HVDC transmission, making it a key equipment for long-distance, large-capacity power transmission (such as cross-regional grid interconnection and new energy grid integration).

  • Up to 1000kV on the grid side.

  • Up to ±1100kV on the valve side.

Features

  • High insulation performance: Operating in a high-voltage environment (often involving ±500kV and above DC voltage), it requires extremely strong insulation capabilities. Special processes such as oil-paper insulation or SF₆ gas insulation are adopted to withstand complex working conditions such as operating overvoltage, lightning overvoltage, and DC bias magnetization.

  • Special winding design: Mostly adopts split winding structures, which can adapt to the multi-bridge arm topology requirements of converter valves. It also reduces harmonic impact on the power grid to ensure power quality.

  • Efficient cooling system: Due to large transmission power (single unit capacity can reach millions of kVA) and high heat generation during operation, it is usually equipped with forced oil circulation directed cooling or forced air cooling systems to ensure stable heat dissipation under rated load.

  • Strong short-circuit resistance: It can withstand short-circuit current impacts during system faults. The windings adopt reinforced mechanical fixing structures to reduce the risk of deformation during short circuits.

  • On-load voltage regulation function: Most products have on-load voltage regulation capabilities, which can adjust the output voltage in real-time according to grid voltage fluctuations, ensuring the converter valve operates within the optimal voltage range and improving system operational flexibility.

  • Adaptability to complex working conditions: It can withstand harmonic waves, DC bias magnetization, vibration, and other unique conditions of DC transmission systems. Metal components undergo high-grade anti-corrosion treatment, adapting to various installation environments such as outdoor or indoor.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Knowledges
Key Points of Online Monitoring Technology for Zinc Oxide Surge Arresters
Key Points of Online Monitoring Technology for Zinc Oxide Surge Arresters
1 Architecture of the Online Monitoring System for Zinc Oxide Surge ArrestersThe online monitoring system for zinc oxide surge arresters comprises three layers: the station control layer, bay layer, and process layer.Station Control Layer: Includes a monitoring center, a Global Positioning System (GPS) clock, and a B - code clock source.Bay Layer: Consists of online monitoring Intelligent Electronic Devices (IEDs).Process Layer: Features monitoring terminals for Potential Transformers (PTs) and
Oliver Watts
07/30/2025
Improvement and Application of the Test Device for Surge Arrester Online Monitor
Improvement and Application of the Test Device for Surge Arrester Online Monitor
1 Significance of Surge Arrester Online Monitors1.1 Enhance Power System Safety, Reduce Lightning DamageDuring lightning strikes, surge arresters play a core role in discharging overvoltage. Online monitors ensure arrester stability, detect potential faults in real - time, and trigger alarms for timely intervention—effectively reducing lightning - induced damage to power equipment and systems, and maintaining stable operation.1.2 Real - Time Status Monitoring, Improve Maintenance Efficienc
Edwiin
07/30/2025
Design of Monitoring System for Surge Arrester in GIS Cubicle of 10kV Power Distribution System for High-Speed Railways
Design of Monitoring System for Surge Arrester in GIS Cubicle of 10kV Power Distribution System for High-Speed Railways
1 Research BackgroundMetal - oxide surge arresters, sealed in cabinets, bear system voltage continuously, risking aging failures, even breakdowns/explosions causing electrical fires. Thus, regular inspection/maintenance is needed. Traditional 3–5 - year - cycle detection (power cut, arrester removal for tests; reinstallation if replaced) poses safety risks and faces space/environment - based standard - grasping difficulties.2 Monitoring Principle of 10kV GIS Cabinet Surge ArresterTo ensure
Dyson
07/30/2025
Can a power transformer designed for 50Hz operate normally at a frequency of 60Hz?
Can a power transformer designed for 50Hz operate normally at a frequency of 60Hz?
Can a 50Hz-Designed Power Transformer Operate on 60Hz Grid?If a power transformer is designed and built for 50Hz, can it run on a 60Hz grid? If so, how do its key performance parameters change?Key Parameter ChangesShort-Circuit Impedance:For a given transformer (same voltage and capacity), short-circuit impedance is proportional to frequency. Thus, a 50Hz-designed unit operating at 60Hz sees a 20% increase—higher frequency intensifies alternating leakage field opposition to current.No-Load
Vziman
07/29/2025
What are the common faults of overhead cables?
What are the common faults of overhead cables?
Overhead cables, due to their exposure to external environments, are subject to various influences that can lead to different types of faults. Below are some common types of faults in overhead cables and their causes:1. Mechanical DamageCaused by external forces such as falling trees, vehicle collisions, or construction accidents.Prolonged vibrations or swinging can also cause material fatigue in cables.2. Weather-Related FaultsLightning Strikes: Direct hits or nearby lightning strikes can cause
Felix Spark
07/29/2025
An Innovative Photoelectromagnetic Cable Eccentricity Measuring Instrument
An Innovative Photoelectromagnetic Cable Eccentricity Measuring Instrument
A core challenge in online cable eccentricity measurement is the cable’s high - speed motion. This requires non - contact measurement equipment that can handle cable jitter. X - ray cable eccentricimeters, based on optical transmission imaging, measure multi - layer contour dimensions to calculate the geometric center of conductors relative to insulation eccentricity. However, they have drawbacks: slow measurement speed (only a few times per second), increased errors from cable jitter, and
Oliver Watts
07/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!