Metal Oxide Surge Arresters for Series Compensation Capacitors

  • Metal Oxide Surge Arresters for Series Compensation Capacitors

Key attributes

Brand ROCKWILL
Model NO. Metal Oxide Surge Arresters for Series Compensation Capacitors
Rated voltage 130kV
Rated frequency 50/60Hz
Series YH43W

Product descriptions from the supplier

Description

Description

Metal Oxide Surge Arresters for Series Compensation Capacitors are specialized protective devices designed to safeguard series compensation capacitor banks in high-voltage AC transmission systems. These arresters are integrated into series compensation circuits—where capacitors enhance power transfer capacity and voltage stability—to mitigate overvoltages caused by system faults, switching transients, or capacitor energization/de-energization. Equipped with high-performance metal oxide varistors (MOVs), they rapidly divert excessive surge currents away from the capacitors, clamping voltage levels to safe thresholds. By preventing damage to capacitor elements, bushings, and associated hardware, these arresters ensure the reliable operation of series compensation systems, maintaining grid efficiency and reducing the risk of unplanned outages.

Features

  • Tailored for Series Compensation Dynamics:Optimized to handle the unique electrical stresses of series capacitor circuits, including high-frequency transients from capacitor switching and fault-induced overvoltages. Designed to match the voltage and current ratings of series compensation banks, ensuring precise protection without compromising system performance.

  • Fast Response to Transients:Incorporates advanced MOVs with ultra-fast response times (microsecond-scale) to suppress sudden voltage spikes—critical for series capacitors, which are highly sensitive to overvoltage durations. This rapid action prevents dielectric breakdown in capacitor elements, even during severe faults.

  • High Energy Absorption Capacity:Engineered to absorb large surge energies generated by faults in series-compensated lines (e.g., line-to-ground faults or capacitor bank failures). The robust MOV design withstands sustained energy pulses, ensuring the arrester itself remains undamaged while protecting the capacitors.

  • Compatibility with Capacitor Protection Schemes:Integrates seamlessly with series compensation protection systems (e.g., spark gaps, bypass switches) to form a layered defense. Coordinates with these devices to share surge current loads, enhancing overall system reliability during extreme events.

  • Durable Construction for Harsh Environments:Housings (typically composite silicone rubber or porcelain) resist environmental stressors such as UV radiation, moisture, and pollution, making them suitable for outdoor installations in diverse climates. Composite options offer lightweight design and hydrophobic properties to reduce flashover risks.

  • Low Leakage Current in Steady State:Maintains minimal leakage current during normal operation, avoiding unnecessary energy loss and heat generation. This ensures efficient performance in series compensation circuits, where steady-state stability is critical for grid voltage regulation.

  • Compliance with Industry Standards:Meets international standards (e.g., IEC 60099-4, IEEE C62.11) for surge arresters in capacitor applications. Undergoes rigorous testing for impulse withstand, thermal stability, and compatibility with series compensation hardware, ensuring safety and interoperability.

  • Long Service Life with Minimal Maintenance:MOVs are designed for long-term stability under cyclic voltage stresses, while durable housings resist aging and corrosion. This reduces maintenance requirements, lowering lifecycle costs for series compensation system operators.

Model 

Arrester

System

Arrester Continuous Operation

DC 1mA

Switching Impulse

Nominal Impulse

Steep - Front Impulse

2ms Square Wave

Nominal

Rated Voltage

Nominal Voltage

Operating Voltage

Reference Voltage

Voltage Residual (Switching Impulse)

Voltage Residual (Nominal Impulse)

Current Residual Voltage

Current - Withstand Capacity

Creepage Distance

kV

kV

kV

kV

kV

kV

kV

A

mm

(RMS Value)

(RMS Value)

(RMS Value)

Not Less Than

Not Greater Than

Not Greater Than

Not Greater Than

20 Times






(Peak Value

(Peak Value

(Peak Value

(Peak Value


YH43W1-130/249W

130

500

76.5

180

249



8000

4200

Y43W1-130/249W

130

500

76.5

180

249



8000

4000

Y20W1-63/149W

63

46.2

500

86

149



8000

2400

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.