Outdoor 27kV/630A SF6 load break switch

  • Outdoor 27kV/630A SF6 load break switch

Key attributes

Brand ROCKWILL
Model NO. Outdoor 27kV/630A SF6 load break switch
Rated voltage 27kV
Rated normal current 630A
Power frequency withstand voltage
Mainly active load breaking current
Series SF6

Product descriptions from the supplier

Description

Description:

  • This is a high standard design SF6 gas load break switch which is suit for pole mounted.

  • RPS type load break switch is KEMA type tested.

  • RPS type load break switch can combined as below different functions switchgear.

  • Manual type load break switch.

  • Motorize type load break switch.

  • Remote control load break switch.

  • Automatic sectionalizer.

Features:

  • the high quality 3 mm stainless steel are used for tank.

  • minimum welding line to minimize corrosion, and specifically to guarantee the safety of the  operation personnel.

  • even with the internal arc faults at the maximum fault capacity of the tank the RPS can  withstands an internal fault without venting hot gases.

  • the independent spring operation mechanism adopt ROCKWILL® patent spiral spring, provides a guaranteed load  break fault make capability by ensuring. the opening and closing speed of the switch.

  • provided with light reflecting position indicator which are directly connected to the switch operating  shaft providing clear and unambiguous switch position. indication

  • indicator made of light reflecting material, which  is easily visible from ground level even at night in driving rain.

Parameters:

image.png

image.png

Monitoring Functions:

image.png

External dimensions:

image.png

Size

889mmx1268mmx557mm

Environmental requirement:

image.png

Product show:

image.png

How to maintain and manage the outdoor load disconnect switch?

Regular Maintenance:

  • Visual Inspection: Conduct regular visual inspections to ensure that the switchgear's housing, connection points, and seals are free from obvious damage or corrosion.

  • Internal Inspection: Perform regular internal inspections, particularly of critical components such as the arc quenching chamber, contacts, and insulating parts, to ensure they are in good condition.

  • Functional Testing: Carry out regular functional tests, including opening and closing operations, insulation resistance testing, and dielectric strength testing, to ensure all functions of the switchgear are operating correctly.

Gas Pressure Monitoring:

  • Pressure Monitoring: For outdoor load break switches using SF6 gas, regularly monitor the SF6 gas pressure in the arc quenching chamber to ensure it remains within the specified range.

  • Leakage Detection: Use leakage detection equipment to regularly check for SF6 gas leaks, and address any detected leaks promptly.

Environmental Control:

  • Temperature Control: Control the installation environment's temperature to avoid high or low temperatures that could affect the performance of the switchgear.

  • Moisture Protection: Implement moisture protection measures to prevent water from entering the switchgear, which could impact its insulation performance and the normal operation of mechanical components.

 

Documentation Resource Library
Restricted
SEC SPECIFICATION FOR MV SMART LINE SECTIONALIZER
Other
English
Consulting
Consulting
Restricted
Pole-Mounted SF6 Load Break Switch(LBS) Catalog
Catalogue
English
Consulting
Consulting
Restricted
Pole Mounted Load Break Switch(LBS) Manual operation
Installation Manual
English
Consulting
Consulting
Restricted
15/27kV SF6 Load break switch(LBS) technology specification
Technical Data Sheet
English
Consulting
Consulting
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Case Studies of Installation and Manufacturing Defects in 110kV HV Circuit Breaker Porcelain Insulators
    1. SF6 gas leakage occurred in the ABB LTB 72 D1 72.5 kV circuit breaker.Inspection revealed gas leakage at the fixed contact and cover plate area. This was caused by improper or careless assembly, where the dual O-rings slipped and were misplaced, resulting in gas leakage over time.2. Manufacturing Defects on the Outer Surface of 110kV Circuit Breaker Porcelain InsulatorsAlthough high-voltage circuit breakers typically have their porcelain insulators protected with covering materials during tra
    12/16/2025
  • Overview of Defect Diagnosis Methods for High-Voltage AC Circuit Breakers
    1. What are the characteristic parameters of the coil current waveform in high-voltage circuit breaker operating mechanisms? How to extract these characteristic parameters from the original trip coil current signal?Answer: The characteristic parameters of the coil current waveform in high-voltage circuit breaker operating mechanisms may include the following: Steady-state peak current: The maximum steady-state current value in the electromagnet coil waveform, representing the position where the
    12/16/2025
  • Chinese tank-type filter manufacturer successfully develops 550 kV tank-type filter bank circuit breaker.
    Good news has come from a Chinese tank-type filter manufacturer: its independently developed 550 kV tank-type filter bank circuit breaker has successfully passed all type tests, marking the official completion of the product’s development.In recent years, with the continuous growth of electricity demand, power grids have placed increasingly higher performance demands on electrical equipment. Keeping pace with the times, the Chinese tank-type filter manufacturer has actively responded to the nati
    11/19/2025
  • Hydraulic Leak & SF6 Gas Leakage in Circuit Breakers
    Leakage in Hydraulic Operating MechanismsFor hydraulic mechanisms, leakage can cause short-term frequent pump starting or excessively long re-pressurization time. Severe internal oil seepage in valves may lead to pressure loss failure. If hydraulic oil enters the nitrogen side of the accumulator cylinder, it can cause abnormal pressure rise, which affects the safe operation of SF6 circuit breakers.Apart from failures caused by damaged or abnormal pressure detection devices and pressure component
    10/25/2025
  • 500kV SF₆ tank circuit breaker insulation pull rod discharge fault cause analysis and treatment
    As a key component of circuit breakers, the insulating pull - rod is an important insulating and transmission part of Gas - Insulated Switchgear (GIS) equipment. It is required to have high reliability in terms of mechanical and electrical properties. Generally, insulating pull - rods rarely malfunction, but once a failure occurs, it can have serious consequences for the circuit breaker.The 550kV circuit breaker in a certain power station has a single - break horizontal arrangement, with the mod
    05/21/2025
  • Research on the Application Mode and Operation Monitoring of Tank-type Circuit Breaker Heating Tapes in 500kV Substations in High-Cold Areas
    At present, most low - voltage switchgear assemblies in China mainly use SF₆ gas at a pressure of 0.5 - 0.6 MPa as the insulating medium. However, when the ambient temperature drops to around - 32.5°C, the SF₆ gas will quickly liquefy, resulting in serious problems with the insulation and interrupting capabilities of the product. To avoid affecting the operation of low - voltage switchgear assemblies in alpine regions, tracing heaters are often used to prevent the liquefaction of SF₆ gas
    05/21/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.