• Outdoor Ring Main Unit (RMU SF6)
  • Outdoor Ring Main Unit (RMU SF6)
  • Outdoor Ring Main Unit (RMU SF6)
Outdoor Ring Main Unit (RMU SF6)
discuss personally
Model
HXGN15-12
Basic info
Brand Wone
Model NO. Outdoor Ring Main Unit (RMU SF6)
Rated voltage 12kV
Series HXGN15
Product Detail

Product overview: 

  • HXGN15-12  Ring Main Unit (SF6 sulfur hexafluoride gas switchgear), box type AC metal closed switchgear.

  • Rated AC frequency 50Hz/ 60Hz, maximum working voltage to 12kV, maximum working current to 4000A.

  • High reliability of operation verification in more than 50 countries and regions around the world,Kuwait, UAE, Saudi Arabia, Iraq, Qatar, Tanzania, Zimbabwe, Ghana, South Africa, Kenya, Zambia, Libya, Myanmar, Philippines, Bangladesh, Nepal,Uzbekistan, Kazakhstan, Kyrgyzstan, Mongolia, Indonesia, Pakistan,Vietnam etc.

  • Mainly used in factories, workshops, residential areas, high-rise buildings and other places of power distribution system, ring network power supply, also suitable for box substation.

  • Meet many international standards: IEC62271-200:2003, GB3906, etc.

Product advantages:
 Leading technology:

  •  Standard anti-corrosion and salt spray environmental plan to meet the stringent environmental requirements of the site.

  •  The components can be equipped with ABB's original HAD/US type ISF6 circuit breaker or VD4-S type vacuum circuit breaker.

  •  SFL-12/24 switchgear with components assembled in China can also be used according to the needs of users.

  •  With perfect and reliable mechanical linkage, interlocking device, fully achieve the "five prevention" function (IP3X).

Cabinet put oneself in another's position:

  •  The whole is made of 2mm hot dip galvanized plate.

  •  Laser numerical control equipment cutting, drilling, bending, to ensure the processing accuracy.

  • The exterior is coated with electrostatic epoxy powder, which will not take off paint for 50 years.

Functional units:

  •  Manual and electric operation, remote control function.

  •  Load switch, combination electrical appliances, its installation mode is flexible, can be installed on the left and right side, front, flip.

  •  Two pressure relief holes, cable room and bus room (load switch) at the back of cabinet.

Busbar system:

  •  High quality three-phase tin bus copper bar, high mechanical strength, good heat dissipation.

 Processing and assembly:

  •  Dust-free workshop to ensure insulation.

  •  Assembly workers have been trained for at least 6 months.

  • Use power tools to ensure proper torque for bolting reinforcement.

  •  The copper bus is CNC cutting, punching and bending to ensure the accuracy.

  • Leybold Helium Mass Spectrometry Leak Detector, Germany -- ensure that the leakage rate of SF6 gas tank is below the national standard.

  •  Computer-controlled equipressure pumping and inflating integrated equipment for vacuum chamber -- to ensure no deformation of gas box and 99.9% purity of SF6 gas.

Product parameters:
Conditions of use:

  •  Altitude shall not exceed 2000m.

  •  Ambient air temperature not higher than +40 ° C, not lower than -5 ° C (average temperature within 24 hours not higher than +35 ° C).

  •  The humidity of the surrounding air should not exceed 50%. Low temperature allows a large relative temperature (e.g. +20 ° C is 90%). Consideration should be given to the effect of condensation caused by temperature changes.

  •  Inclination with vertical plane is not more than 5°, and the whole group of cabinets is relatively flat, in line with (GBJ232-2) standard.

  •  Requested in no violent vibration and impact, electrical components will not be corroded, no conductive dust place.

Ordering instructions:
The customer shall provide the following information:

  • Main loop scheme diagram, secondary loop system diagram and auxiliary circuit control mode.

  • Equipment layout and distribution room layout.

  • Brand and model of main electrical components of the equipment.

  • Incoming and outgoing lines.

  • Other special requirements can be negotiated with WONE Electric.

What are the structural characteristics of the RMU SF6?

Fully Sealed and Fully Insulated:

  • SF6 gas has excellent insulating properties. The ring main unit (RMU) uses SF6 gas for common box insulation, with all switching components sealed within the main enclosure. This design effectively prevents external environmental factors such as condensation, contamination, and flooding from affecting the internal electrical components, ensuring safe and reliable operation. The protection level typically reaches IP67.

Compact and Space-Efficient:

  • The design is compact, requiring a small footprint, allowing it to be installed in limited spaces. It is suitable for various outdoor locations, such as city streets, residential areas, and industrial parks, effectively saving space resources.

Corrosion-Resistant Design:

  • The enclosure is typically designed with special anti-corrosion features and painted with a protective coating, providing good resistance to corrosion. This allows the equipment to withstand harsh environmental conditions such as acid rain and salt fog, extending its service life.



Know your supplier
Wone
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!