Pole fuse switch disconnector for protecting underground cables

  • Pole fuse switch disconnector for protecting underground cables

Key attributes

Brand Wone Store
Model NO. Pole fuse switch disconnector for protecting underground cables
Rated frequency 50/60Hz
Series SZ

Product descriptions from the supplier

Description

Product Introduction

The Pole Fuse Switch Disconnector for Protecting Underground Cables is a specialized electrical device designed to safeguard underground low-voltage (LV) cable networks. Mounted on poles at junction points between overhead lines and underground cables, it acts as a critical protective barrier—preventing damage to buried cables from overloads, short circuits, or voltage surges. It integrates switching, isolation, and fuse-based protection to manage power flow between overhead grids and underground systems, ensuring reliable operation in residential, commercial, and industrial areas where underground cabling is prevalent.

Core Features

  • Underground Cable-Specific Protection:Tailored to address the unique risks of underground cables (e.g., moisture-induced faults, insulation degradation), it provides targeted protection against overloads and short circuits that could damage buried conductors. Prevents costly cable replacements and network outages.

  • Seamless Overhead-to-Underground Integration:Designed to connect overhead lines with underground cables, creating a secure transition point. The pole-mounted structure simplifies installation at cable entry/exit points (e.g., near transformers or distribution cabinets), ensuring efficient power transfer between systems.

  • Enhanced Isolation for Cable Maintenance:Enables safe isolation of underground cable sections during repairs or inspections. Clear position indicators and lockable open positions prevent accidental re-energization, allowing technicians to work on buried cables without risk of electric shock.

  • Weather-Resistant Construction:Built with durable, corrosion-resistant materials (e.g., coated metals, UV-stable plastics) to withstand outdoor elements at pole-mounted locations. Sealed fuse compartments protect internal components from moisture, dust, and debris—critical for reliable operation near underground cable entry points.

  • Easy Fault Identification:Many models feature visual fuse failure indicators, allowing quick identification of tripped fuses. This speeds up troubleshooting, reducing downtime for underground cable networks and ensuring faster restoration of power.

Main Parameters

Certificates

Standards

IEC 60947-3, IEC 60947-1

Dimensions

Weight

9.1 kg

Height

402 mm

Width

319 mm

Length

463 mm

Electrical values

Nominal insulation voltage

1000 V

Features

Connectors included

3xKG43.6

Number of poles

3

Utilization category

AC22B

ETIM

ETIM Class

EC001040

Max. rated operation voltage Ue AC

500 V

Rated permanent current Iu

400 A

Suitable for fuses

NH2

Number of poles

3

Type of electrical connection of main circuit

Cable clamp

Type of control element

Long turning handle

 

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings/Instrument Transformer/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Dedicated Vacuum Contactor Solution for Port Shore Power Systems
    I. Background and Challenges​Shore power systems have become core technical equipment for ports to reduce carbon emissions and noise pollution. However, these systems face two major challenges in the harsh operational environment of ports:​Severe Environmental Corrosion: High humidity and salt spray in port areas cause serious corrosion to metal components and enclosures of electrical equipment, significantly impacting electrical lifespan and operational reliability.​High Switching Requirements:
    09/13/2025
  • ABB Vacuum Contactor KC2 Power Supply System Technical Transformation Plan
    Issue Overview​The 10kV air compressor starting system of a company utilizes the ABB vacuum contactor KC2 as the control component for the operating circuit. The dedicated wide-voltage power supply module paired with this contactor presents the following issues:​Frequent failures: The power supply module fails to properly transition the voltage from 300V to 12V, resulting in fuse blowouts.​Poor heat dissipation: Enclosed installation of the module leads to insufficient heat dissipation, acceler
    09/13/2025
  • Solution for Medium-Voltage Motor Control and Protection Using Vacuum Contactor-Fuse (VCF) in a Coal Conveying System
    1.Project BackgroundA coal conveying system comprises 15 belt conveyors driven by medium-voltage motors. The system operates under complex conditions, with motors often subjected to heavy loads and frequent starts. To address these challenges and achieve effective control and reliable protection during motor startup, the project comprehensively adopts Vacuum Contactor-Fuse (VCF) combination devices for the 6kV medium-voltage motor power distribution. This solution details the technical features,
    09/13/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.