IEE Business offers free, AI-powered tools for electrical engineering design and power procurement budgeting: enter your parameters, click calculate, and get instant results for transformers, wiring, motors, power equipment costs, and more — trusted by engineers worldwide.
The RMRSVG pole-mounted outdoor compensation device is designed to address the critical power-quality issues commonly found in modern distribution networks. It fully aligns with national guidelines for low-voltage governance and distribution network optimization. By providing fast, precise, and continuous compensation, it effectively resolves three-phase imbalance, low end-of-line voltage, reverse power flow reactive current, and harmonic pollution in distribution systems.
This device improves overall voltage quality, raises terminal voltage levels, enhances power supply reliability, and stabilizes end-user operating conditions. By correcting phase imbalance, it significantly reduces energy losses within low-voltage feeders and distribution transformers, extending transformer service life. It also supports local reactive power balancing, increases distribution capacity, and ensures excellent harmonic mitigation even under nonlinear load conditions.
Product Details
Working Principle
The RMRSVG device uses advanced power electronics and real-time digital control to inject or absorb reactive power and unbalanced currents dynamically. An intelligent algorithm monitors system parameters such as phase voltage, current distortion, load imbalance, and harmonic levels, providing rapid compensation through an IGBT-based inverter module.
When the system exhibits unbalanced loads or fluctuating voltage, the HYSVG instantly delivers corrective currents to restore phase symmetry, stabilize voltage, and suppress harmonic components. This ensures improved voltage regulation accuracy and reduces the thermal burden on cables and transformers.
Key Features
Real-time three-phase imbalance correction with fast dynamic response.
Significant voltage improvement, especially for end-of-line low-voltage feeders.
Local reactive power balancing, reducing transformer loading and enhancing capacity.
Advanced harmonic suppression, suitable for nonlinear loads such as EV chargers, inverters, and industrial equipment.
Fully automated digital control with continuous monitoring and adaptive compensation.
Weatherproof outdoor design, suitable for pole-mounted applications in harsh environments.
High reliability, low maintenance, and long service life.
Improves distribution efficiency, reduces system loss, and stabilizes user-side power supply.
Product Features & Functions
Corrects current imbalance within low-voltage distribution networks.
Compensates excessive neutral-line current.
Provides dynamic reactive power compensation to stabilize voltage quality.
Suppresses harmonics and improves overall power quality.
Supports WiFi local wireless monitoring via handheld terminal.
Optional GPRS remote monitoring for cloud-based supervision.
Allows flexible phase-sequence connection; no fixed wiring order is required.
Technical Specifications
Reactive Compensation Capacity Options
Rating (kvar)
30
50
100
150
Rated Voltage
380 V (±20% allowable fluctuation)
Frequency
50 Hz (±2%)
Wiring Method
Three-phase three-wire
Current Transformer
Optional external CT input (Class 0.5 accuracy or above, ≥5 VA; secondary CT recommended: 5 A)
Overall Efficiency
≥97%
System Power Consumption
≤3% of rated power
Switching Frequency
20 kHz
Reactive Power Compensation
Achievable compensation accuracy ≥95%.
Power factor after compensation can reach up to 0.99.
Automatically avoids over-compensation.
Harmonic Compensation
Supports compensation for the 2nd to 13th harmonic orders.
Control Technology
Three-level digital vector control algorithm.
Precise detection of voltage and current waveform distortion for active harmonic suppression.
Enclosure Dimensions: 978 mm (H) × 485 mm (D) × 465 mm (W) (Other sizes available upon request.)
Material: Stainless steel or galvanized steel plate.
Cable Entry: Side cable entry.
Monitoring & Communication
Local Monitoring
Wireless handheld terminal.
Full-parameter viewing and real-time status monitoring via WiFi.
Remote Monitoring
GPRS-based cloud monitoring platform.
Supports data reporting, remote parameter management, fault alarms, and historical data review.
Operational Characteristics
Full-system protection including overtemperature, overvoltage, undervoltage, overcurrent, short-circuit, module overload, and grid-abnormal detection.
Rapid compensation under varying load conditions.
Stable continuous operation without resonance risks.
If grid anomalies occur or the power supply is unstable, the internal protection algorithm isolates device modules from the grid, ensures safekeeping, and restores operation automatically after conditions normalize.
When external power supply quality severely deteriorates, the device automatically switches to protection mode, preventing faults caused by abnormal grid conditions.
Appearance & Dimensions
Pole-Mounted Outdoor Enclosure (Description corresponds to the diagram you provided.)
Front shade-protected waterproof structure.
Designed for pole-mounting in distribution networks.
Lockable maintenance door with anti-tamper mechanism.
Rear ventilation grids and heat dissipation structure.
Workplace: 30000m² Total staff: Highest Annual Export(usD): 100000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Robot
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.
What is Electrical Energy?Before explaining what electrical energy is, let us try to review the potential difference between two points in an electric field.Suppose potential difference between point A and point B in an electric is v volts.As per the definition of potential difference we can say, if one positive unit electrical charge that is a body containing one-coulomb positive charge travels from point A to point B, it will do v joules work.Now instead of one-coulomb charge if q coulomb char
Haven't found the right supplier yet? Let matching verified suppliers find you.Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
×
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.