SF6 Gas-insulated RMU Ring Main Unit

  • SF6 Gas-insulated RMU Ring Main Unit

Key attributes

Brand ROCKWILL
Model NO. SF6 Gas-insulated RMU Ring Main Unit
Rated voltage 12kV
Rated frequency 50/60Hz
Series RMU

Product descriptions from the supplier

Description
Description
The SF6 Gas-insulated RMU (Ring Main Unit) is a compact, high-performance medium-voltage electrical equipment designed for power distribution networks. It utilizes SF6 gas as the insulating and arc-extinguishing medium, integrating core components such as load switches, grounding switches, and busbars into a sealed enclosure. Widely applied in urban power grids, industrial parks, commercial complexes, and renewable energy projects, it plays a critical role in controlling, protecting, and distributing electrical power efficiently and safely.

The ring network switchgear is suitable for receiving and distributing electric energy in the power network of 50Hz and 12kV. The main switch in the cabinet is SF6 switch.

Key Features
  • Superior SF6 Insulation Performance: SF6 gas provides exceptional dielectric strength and arc-extinguishing capabilities, ensuring stable operation in medium-voltage environments (typically 12kV, 24kV, etc.). It effectively blocks current leakage, minimizing risks of short circuits and flashovers to guarantee grid reliability.
  • Compact and Space-Saving Design: The sealed, integrated structure reduces overall size significantly, making it ideal for space-constrained installations such as indoor substations or urban areas with limited land. It simplifies on-site layout and improves land utilization.
  • Enhanced Safety and Reliability: Equipped with comprehensive mechanical and electrical interlocks to prevent misoperations (e.g., incorrect switching or grounding). Built-in SF6 gas leakage monitoring systems provide real-time alerts, complying with international safety standards and ensuring safe operation and maintenance.
  • Low Maintenance and Long Lifespan: The hermetic enclosure isolates internal components from dust, moisture, and corrosive elements, reducing wear and tear. This design enables long-term maintenance-free operation, with a service life of up to 20 years, lowering lifecycle costs.
  • Flexible Adaptability: Supports multiple wiring configurations (e.g., ring network, radial distribution) and can be seamlessly connected with transformers, cables, and other equipment. It accommodates diverse grid topologies, meeting varying power distribution needs in industrial, commercial, and utility scenarios.
  • Environmental and Economic Balance: SF6 gas is recyclable and reusable, minimizing resource waste. Its high efficiency and durability reduce energy loss and equipment replacement frequency, balancing environmental responsibility with long-term economic benefits.

Working conditions

  • Ambient temperature: upper limit +40°C, lower limit -25°C.
  • Altitude: the altitude does not exceed 2000m.
  • Relative temperature: the daily average is not more than 95%; the monthly average is not more than 90%.
  • Surrounding environment: the surrounding air is not obviously polluted by corrosive gas or combustible gas, water vapor, etc.
  • No frequent violent vibration.
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.