Solid insulated ring main unit accessories 260 umbrella shaped sleeve seat

  • Solid insulated ring main unit accessories 260 umbrella shaped sleeve seat

Key attributes

Brand Switchgear parts
Model NO. Solid insulated ring main unit accessories 260 umbrella shaped sleeve seat
Rated voltage 12kV
Rated normal current 630A
Series 260

Product descriptions from the supplier

Description

The 260 umbrella shaped bushing seat is a specialized insulation support accessory for 12kV/24kV SF6 free solid insulated ring main unit. Its core is used for fixing and insulation protection of bushing components, and is compatible with the installation requirements of the 260 specification.
Core Features
Made of solid insulation material, free from SF6 gas pollution, in line with green distribution and environmental protection requirements, with stable insulation performance.
Umbrella shaped structure design enhances creepage distance and anti pollution flashover capability, suitable for complex environments such as outdoor and industrial plants.
The size accurately matches the 260 specification sleeve, with a compact structure and high mechanical strength, firmly fixed without looseness.
Resistant to aging and corrosion, with excellent sealing protection, easy installation, and long-term stability of casing operation.
Applicable scenarios
Suitable for 12kV/24kV SF6 free solid insulated ring main unit, used to support fixed incoming and outgoing line sleeves, PT sleeves and other components, widely used in medium voltage distribution systems such as urban distribution networks, industrial distribution, and new energy power stations.

Product dimensions

FAQ
Q: What advantages does 260 umbrella-type bushing holder have compared with ordinary bushing holders?
A:

It has three key advantages: ① Anti-pollution performance: The umbrella-shaped structure effectively extends creepage distance, reducing the risk of pollution flashover in dusty, humid environments; ② Stable support: High-strength epoxy resin material ensures strong load-bearing capacity, preventing bushing loosening or tilting during long-term operation; ③ Environmental protection: SF6-free design, in line with global carbon neutrality requirements, no gas leakage risk, maintenance-free; ④ Precise matching: Standard 260 size, perfectly compatible with 260 series bushings, easy to install and replace.

Q: What is the core function and working principle of 260 umbrella-type bushing holder?
A:

 It is a specialized mounting and insulation accessory for high-voltage bushings in 10kV/12kV ring main units (RMU) and inflatable cabinets. Core functions: ① Fix and support bushings stably to prevent displacement during operation; ② Cooperate with the umbrella structure to extend creepage distance and improve anti-pollution performance; ③ Enhance insulation isolation between bushings and cabinet bodies. Its working principle relies on high-strength epoxy resin material for mechanical support and insulation, and the umbrella-shaped structure blocks the formation of conductive paths on the surface, ensuring safe operation in harsh environments.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.